Performance evaluation of PLL algorithms for single-phase grid-connected systems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Phase angle, frequency and amplitude of the utility voltage vector are basic information for an increasing number of grid-connected power conditioning equipments, such as PWM rectifiers, uninterruptible power systems (UPS), voltage sag compensators and the emerging distributed generation systems. For these applications, accurate tracking of the utility voltage vector is essential to ensure correct operation of the control system. This paper presents a comparative study of synchronous reference frame PLL algorithms for single-phase systems. Simulation and experimental results, including operation of the PLL structures under distorted utility conditions are presented, to allow a performance evaluation of the PLL algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Signal Processing : A Computer-Based Approach
Mitra, S. (1997) · Cited by 2,115
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
Cited by
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
Dynamics Assessment of Advanced Single-Phase PLL Structures
Golestan, S., Monfared, M., Freijedo, F. D., & Guerrero, J. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2193863 · Cited by 371
Metadata
- Authors
- Silva, S. M., Lopes, B. M., Cardoso Filho, B. J., Campana, R. P., & Boaventura, W. C.
- Venue
- Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.
- Publisher
- IEEE
- Published
- 2004-11-08
- Volume
- 4
- Pages
- 2259-2263
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2130961118
- Cited by
- 343
- References
- 4
- FWCI
- 10.25
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).