Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 469

The DOI matches its Crossref record.

Comparison of Three Single-Phase PLL Algorithms for UPS Applications

Santos Filho, Rubens M., Seixas, Paulo F., Cortizo, PorfÍrio C., Torres, Leonardo A. B., Souza, AndrÉ F.·2008·IEEE Transactions on Industrial Electronics

Abstract

In this paper, the performance assessment of three software single-phase phase-locked loop (PLL) algorithms is carried out by means of dynamic analysis and experimental results. Several line disturbances such as phase-angle jump, voltage sag, frequency step, and harmonics are generated by a DSP together with a D/A converter and applied to each PLL. The actual minus the estimated phase-angle values are displayed, providing a refined method for performance evaluation and comparison. Guidelines for parameters adjustments are also presented. In addition, practical implementation issues such as computational delay effects, ride-through, and computational load are addressed. The developed models proved to accurately represent the PLLs under real test conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2008.924205

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 469

Metadata

Authors
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F.
Venue
IEEE Transactions on Industrial Electronics
Published
2008-08
Volume
55
Issue
8
Pages
2923-2932
ISSN
0278-0046 (ISSN-L)
OpenAlex
W2110243397
Cited by
469
References
0
FWCI
40.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Three Single-Phase PLL Algorithms for UPS Applications. https://app.cochat.ai/papers/10.1109/tie.2008.924205
The paper
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008). Comparison of Three Single-Phase PLL Algorithms for UPS Applications. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2008.924205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.