Digital Active Power Filter Controller Design for Current Harmonics in Power System
Abstract
Nonlinear loads are essential part of power system. With the advancement in power electronics, switching elements have major share in electrical load. These elements create nonlinearities in lines increasing the line losses, reducing power quality and purity of sin wave. Passive filters work fine for harmonic elimination for specific frequencies which are considered in design specification. Active filters on the other hand work according to harmonics currently in line. Active filter designed in this work consists of a shunt active power filter that compensates current harmonic due to non-linear load. The active filter has a voltage source converter (VSC) which works in back to back configuration with a DC coupling capacitor. Power is injected by the VCS at the point of common coupling (PCC). The reference current is generated using instantaneous power theory. The harmonic components are separated from reference current, the reference is compared with actual current and the pulse width to control VSC is adjusted by the controller. The strength of proposed approach is illustrated through simulation in MATLAB software. The simulation results are then cross verified in real time using experimental setup. Total harmonic distortion (THD) of line current analyzed by fast Fourier transform (FFT) analysis is reduced to 4.56% from 28%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- 10.1109/61.400941 · DOI
- 10.1109/28.556633 · DOI
- 10.1109/TPEL.2015.2509510 · DOI
- 10.1016/S0378-7796(01)00141-9 · DOI
- 10.1109/PCC.2002.998518 · DOI
- 10.1109/63.285498 · DOI
- 10.1109/61.956770 · DOI
- 10.1109/28.52679 · DOI
- 10.1109/TIA.2003.821666 · DOI
- 10.1109/63.662847 · DOI
- 10.1109/TIA.1984.4504460 · DOI
- 10.1002/9780470754245 · DOI
- 10.1002/0470118938 · DOI
Cited by
Sorted by citations
Kadir Sheikh, S., Jain, M., & Chandrakant Tapre, P. (2025) · Tehnički glasnik · doi:10.31803/tg-20230822132129 · Cited by 2
“The ASD method is used in industrial applications because distinct equipment in various sectors operates at distinct speeds [21].”
Metadata
- Authors
- Ullah, A., Sheikh, I. U. H., Arshad, S., & Saleem, F.
- Affiliations
- University of Engineering and Technology Taxila (PK)
- Venue
- 2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST)
- Publisher
- IEEE
- Published
- 2019-01
- Pages
- 384-388
- OpenAlex
- W2921577623
- Cited by
- 21
- References
- 0
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 2 · 2022: 5 · 2021: 4 · 2020: 5 · 2019: 1
- FWCI
- 5.97
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- International Bhurban Conference on Applied Sciences and Technology (IBCAST) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- active power filter, current harmonics, nonlinear loads, shunt active power filter, voltage source converter, back-to-back converter, point of common coupling, instantaneous power theory, total harmonic distortion reduction, power quality, PWM control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review