Compressed sensing based method for ECG compression
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Compressive sensing (CS) is a new approach for the acquisition and recovery of sparse signals that enables sampling rates significantly below the classical Nyquist rate. Based on the fact that electrocardiogram (ECG) signals can be approximated by a linear combination of a few coefficients taken from a Wavelet basis, we propose a compressed sensing-based approach for ECG signal compression. ECG signals generally show redundancy between adjacent heartbeats due to its quasi-periodic structure. We show that this redundancy implies a high fraction of common support between consecutive heartbeats. The contribution of this paper lies in the use of distributed compressed sensing to exploit the common sup port between samples of jointly sparse adjacent beats. Simulation results suggest that compressed sensing should be considered as a plausible methodology for ECG compression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 3×
“In recent years, CS theory [4] has generated significant interest in the signal processing community because of its potential to enable signal reconstruction from significantly fewer data samples than suggested by conventional sampling theory.”
BackgroundInfluentialSparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Cited by
Enabling technologies for green Internet of Things
Shaikh, F. K., Zeadally, S., & Exposito, E. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2015.2415194 · Cited by 382
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2226175 · Cited by 340
A neural algorithm for the non-uniform and adaptive sampling of biomedical data
Mesin, L. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.02.004 · Cited by 22
“of the MIT-BIH Arrhythmia Database considered in [23,39] is”
MethodPham, N., Jia, H., Tran, M., Dinh, T., Bui, N., Kwon, Y., Ma, D., Nguyen, P., Mascolo, C., & Vu, T. (2022) · Proceedings of the 28th Annual International Conference on Mobile Computing And Networking · doi:10.1145/3495243.3560533 · Cited by 12
Metadata
- Authors
- Polania, L. F., Carrillo, R. E., Blanco-Velasco, M., & Barner, K. E.
- Venue
- 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP)
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 761-764
- ISSN
- 1520-6149 (ISSN-L)
- OpenAlex
- W2106759147
- Cited by
- 153
- References
- 2
- FWCI
- 27.07
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compressed sensing based method for ECG compression. https://app.cochat.ai/papers/10.1109/icassp.2011.5946515
- The paper
- Polania, L. F., Carrillo, R. E., Blanco-Velasco, M., & Barner, K. E. (2011). Compressed sensing based method for ECG compression. 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). https://doi.org/10.1109/icassp.2011.5946515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.