CoChat

Quantification of Parkinson's disease characteristics using wireless accelerometers

LeMoyne, Robert, Coroian, Cristian, Mastroianni, Timothy · 2009 · 2009 ICME International Conference on Complex Medical Engineering
Cited by 67

The DOI matches its Crossref record.

Abstract

Parkinson's disease is classified as a chronic movement disorder. The incidence of Parkinson's disease is proportional to age. The status of Parkinson's disease is characterized through the Unified Parkinson's Disease Rating Scale. The Unified Parkinson's Disease Rating Scale is an ordinal scale, for which the scale is qualitatively evaluated. The inherent issue of the ordinal scale is the lack of a temporal parameter to evaluate the attributes of the movement disorder. The evaluation of the Parkinson's Disease Rating Scale requires clinical specialization, occurring in a clinical environment. Accelerometers, through the advent of miniaturization, have reached a capacity to advance the evaluation of Parkinson's disease. Tremor characteristics and temporal attributes of Parkinson's disease can be readily quantified. Accelerometer systems have been tested and evaluated for ascertaining general status, drug therapy efficacy, and amelioration of Parkinson's disease based on deep brain stimulation parameter settings. Further advance of the accelerometer characterization of Parkinson's disease attributes involves the incorporation of a fully wearable system. Such a system is possible with the integration of wireless 3D MEMS accelerometers. The device proposed incorporates a wireless and potentially wearable 3D MEMS accelerometer mounted on the dorsum of the hand. The wireless 3D MEMS accelerometer system can potentially track the Parkinson's disease status through out real time for a subject at the home-based setting of the subject. An implication of the device is a subject database can be generated quantifying the progression of Parkinson's disease. Drug therapy dosage may be optimized with quantified feedback from the wireless 3D MEMS accelerometer system. Deep brain stimulation parameters may be further refined, and the conceptual foundation for real time deep brain stimulation parameter optimization is established. Enclosed is the initial test and evaluation of the wireless 3D MEMS accelerometer system through the quantification of simulated tremor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iccme.2009.4906657

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 67

Metadata

Authors
LeMoyne, R., Coroian, C., & Mastroianni, T.
Venue
2009 ICME International Conference on Complex Medical Engineering
Publisher
IEEE
Published
2009-04
Pages
1-5
OpenAlex
W2131534334
Cited by
67
References
0
FWCI
16.54
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Parkinson's disease characteristics using wireless accelerometers. https://app.cochat.ai/papers/10.1109/iccme.2009.4906657
The paper
LeMoyne, R., Coroian, C., & Mastroianni, T. (2009). Quantification of Parkinson's disease characteristics using wireless accelerometers. 2009 ICME International Conference on Complex Medical Engineering. https://doi.org/10.1109/iccme.2009.4906657

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.