The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Robust Heart Rate Measurement from Video Using Select Random Patches
Abstract
The ability to remotely measure heart rate from videos without requiring any special setup is beneficial to many applications. In recent years, a number of papers on heart rate (HR) measurement from videos have been proposed. However, these methods typically require the human subject to be stationary and for the illumination to be controlled. For methods that do take into account motion and illumination changes, strong assumptions are still made about the environment (e.g. background can be used for illumination rectification). In this paper, we propose an HR measurement method that is robust to motion, illumination changes, and does not require use of an environment's background. We present conditions under which cardiac activity extraction from local regions of the face can be treated as a linear Blind Source Separation problem and propose a simple but robust algorithm for selecting good local regions. The independent HR estimates from multiple local regions are then combined in a majority voting scheme that robustly recovers the HR. We validate our algorithm on a large database of challenging videos.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417 · cited 3×
“[7] also extracts the PG signal under challenging conditions.”
BackgroundInfluential
Cited by
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Yu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340
PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
Metadata
- Authors
- Lam, A., & Kuno, Y.
- Venue
- 2015 IEEE International Conference on Computer Vision (ICCV)
- Publisher
- IEEE
- Published
- 2015-12
- Pages
- 3640-3648
- OpenAlex
- W2218803975
- Cited by
- 176
- References
- 2
- FWCI
- 24.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.