DistancePPG: Robust non-contact vital signs monitoring using a camera
Open accessAbstract
Vital signs such as pulse rate and breathing rate are currently measured using contact probes. But, non-contact methods for measuring vital signs are desirable both in hospital settings (e.g. in NICU) and for ubiquitous in-situ health tracking (e.g. on mobile phone and computers with webcams). Recently, camera-based non-contact vital sign monitoring have been shown to be feasible. However, camera-based vital sign monitoring is challenging for people with darker skin tone, under low lighting conditions, and/or during movement of an individual in front of the camera. In this paper, we propose distancePPG, a new camera-based vital sign estimation algorithm which addresses these challenges. DistancePPG proposes a new method of combining skin-color change signals from different tracked regions of the face using a weighted average, where the weights depend on the blood perfusion and incident light intensity in the region, to improve the signal-to-noise ratio (SNR) of camera-based estimate. One of our key contributions is a new automatic method for determining the weights based only on the video recording of the subject. The gains in SNR of camera-based PPG estimated using distancePPG translate into reduction of the error in vital sign estimation, and thus expand the scope of camera-based vital sign monitoring to potentially challenging scenarios. Further, a dataset will be released, comprising of synchronized video recordings of face and pulse oximeter based ground truth recordings from the earlobe for people with different skin tones, under different lighting conditions and for various motion scenarios.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other subjective scales were employed in 13 studies (35.14%).
“and other subjective scales were employed in 13 studies (35.14%) [30,42,43,44,45,50,52,56,72,78,80,87,88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [78]
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893 · see citing works
Shi, J., & Tomasi (1994) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition CVPR-94 · doi:10.1109/cvpr.1994.323794 · Cited by 7,724 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728 · see citing works
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652 · see citing works
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M., McDuff, D., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,488 · see citing works
Linear diversity combining techniques
Brennan, D. G. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808163 · Cited by 822 · see citing works
Deformable Model Fitting by Regularized Landmark Mean-Shift
Saragih, J. M., Lucey, S., & Cohn, J. F. (2011) · International Journal of Computer Vision · doi:10.1007/s11263-010-0380-4 · Cited by 787 · see citing works
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287 · see citing works
Wieringa, F. P., Mastik, F., & van der Steen, A. F. W. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5763-2 · Cited by 284 · see citing works
Aarts, L. A. M., Jeanne, V., Cleary, J. P., Lieber, C. A., Nelson, J. S., Oetomo, S. B., & Verkruysse, W. (2013) · Early Human Development · doi:10.1016/j.earlhumdev.2013.09.016 · Cited by 241 · see citing works
The difference in pulse transit time to the toe and finger measured by photoplethysmography
Nitzan, M., Khanokh, B., & Slovik, Y. (2001) · Physiological Measurement · doi:10.1088/0967-3334/23/1/308 · Cited by 218 · see citing works
Humphreys, K., Ward, T. E., & Markham, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2724789 · Cited by 214 · see citing works
Sun, Y., Hu, S., Azorin-Peris, V., Chambers, J. A., Zhu, Y., & Greenwald, S. E. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602852 · Cited by 213 · see citing works
Heathers, J. A. J. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.05.017 · Cited by 122 · see citing works
Signal recovery in imaging photoplethysmography
Holton, B. D., Mannapperuma, K., Lesniewski, P. J., & Thomas, J. C. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/11/1499 · Cited by 73 · see citing works
Evaluation of a New Pulse Oximeter Sensor
Fernandez, M., Burns, K., Calhoun, B., George, S., Martin, B., & Weaver, C. (2007) · American Journal of Critical Care · doi:10.4037/ajcc2007.16.2.146 · Cited by 66 · see citing works
Opto‐Physiological Modeling Applied to Photoplethysmographic Cardiovascular Assessment
Hu, S., Azorin-Peris, V., & Zheng, J. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.4.505 · Cited by 30 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234 · see citing works
“For a thorough evaluation, we benchmark it with seven commonly used or state-of-the-art rPPG methods: 1) G (2007) [1], the single wavelength method that is still popular as evidenced by recent researches [7], [10].”
MethodPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 567 · see citing works
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2019) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 421 · see citing works
“[21] Webcam G Patch level signals combination FFT using weighted average”
MethodWireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414 · see citing works
“, DistancePPG [129]) and sensor-based (e.”
A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments
Ghamari, M., Janko, B., Sherratt, R. S., Harwin, W., Piechocki, R. J., & Soltanpur, C. (2016) · Sensors · doi:10.3390/s16060831 · Cited by 300 · see citing works
“For example, researchers from Rice University have been developing a non-contact video-camera system that can precisely monitor and measure temperature, pulse and breathing rate from changes in a patient’s skin color [99].”
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R. K., & Wang, Z. J. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 228 · see citing works
“illumination variations [31], [32], [42]–[44].”
BackgroundMethodInfluentialKim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 238 · see citing works
“Multi-wavelength PPG sensing technology is widely recognized as a robust method for the measurement of PPG signals [92,93].”
SynRhythm: Learning a Deep Heart Rate Estimator from General to Specific
Niu, X., Han, H., Shan, S., & Chen, X. (2018) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2018.8546321 · Cited by 196 · see citing works
“In [15], Kumar et al.”
3D Mask Face Anti-spoofing with Remote Photoplethysmography
Liu, S., Yuen, P. C., Zhang, S., & Zhao, G. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-46478-7_6 · Cited by 194 · see citing works
“rPPG signals are weak (around ±2 variations for a 8-bit color camera [28]) since only a small portion of light can transmit to blood vessels as quite amount of light energy is reflected or absorbed by human skin.”
BackgroundRemote heart rate measurement using low-cost RGB face video: a technical literature review
Rouast, P. V., Adam, M., Chiong, R., Cornforth, D., & Lux, E. (2018) · Frontiers of Computer Science · doi:10.1007/s11704-016-6243-6 · Cited by 188 · see citing works
“[31] used an algorithm for deformable model fitting; and Saragih et al.”
BackgroundMethodInfluentialHeart rate estimation using facial video: A review
Hassan, M. A., Malik, A. S., David Fofi, B., Saad, M. N. M., Karasfi, B., Ali, Y. S., & Mériaudeau, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.07.004 · Cited by 183 · see citing works
“[5], proposed PPG estimation method by using a monochrome camera with a green spectrum filter.”
BackgroundMethodInfluentialRobust Heart Rate Measurement from Video Using Select Random Patches
Lam, A., & Kuno, Y. (2015) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.415 · Cited by 180 · see citing works
“[7] also extracts the PG signal under challenging conditions.”
BackgroundInfluentialSparsePPG: Towards Driver Monitoring Using Camera-Based Vital Signs Estimation in Near-Infrared
Nowara, E. M., Marks, T. K., Mansour, H., & Veeraraghavan, A. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00174 · Cited by 174 · see citing works
“[14], we throw away a region if its signal-to-noise ratio (SNR) is below a threshold θSNR or if its maximum amplitude is above a threshold θamp.”
BackgroundMethodInfluentialNon-contact measurement of oxygen saturation with an RGB camera
Guazzi, A., Villarroel, M., Jorge, J., Daly, J., Frise, M. C., Robbins, P. A., & Tarassenko, L. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003320 · Cited by 151 · see citing works
Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging.
Cho, Y., Julier, S., Marquardt, N., & Bianchi-Berthouze, N. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.004480 · Cited by 130 · see citing works
Smartphone-based imaging systems for medical applications: a critical review
Hunt, B., Ruiz, A. J., & Pogue, B. W. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.4.040902 · Cited by 141 · see citing works
“recent development which more fully utilizes the spatial information provided by smartphone imaging.(68,72,104,123,124) Two recent works, by Park et al.”
MethodDiraco, G., Leone, A., & Siciliano, P. A. (2017) · Biosensors · doi:10.3390/bios7040055 · Cited by 135 · see citing works
“The working principle of cbPPG is to detect small changes in the skin color due to cyclic variations of blood volume in arteries and capillaries under skin, and thus to estimate the PPG signal which is proportional to such skin color changes [71].”
BackgroundUnobtrusive Vital Sign Monitoring in Automotive Environments—A Review
Leonhardt, S. K., Leicht, L., & Teichmann, D. (2018) · Sensors · doi:10.3390/s18093080 · Cited by 135 · see citing works
Sensors, vision and networks: From video surveillance to activity recognition and health monitoring
Prati, A., Shan, C., & Wang, K. I. (2019) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-180510 · Cited by 135 · see citing works
“A weighted averaging method was proposed in [72], where a higher weight is assigned to pixels that contain a stronger PPG signal and a lower weight to those with weaker signal.”
MethodInternet of Things Based Wireless Body Area Network in Healthcare
Elhayatmy, G., Dey, N., & Ashour, A. S. (2017) · Studies in big data · doi:10.1007/978-3-319-60435-0_1 · Cited by 130 · see citing works
Contrast-Phys: Unsupervised Video-Based Remote Physiological Measurement via Spatiotemporal Contrast
Sun, Z., & Li, X. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-19775-8_29 · Cited by 127 · see citing works
“Several works [17,48,16,53,51,22,21] also exploited rPPG spatial similarity to design their methods.”
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124 · see citing works
A Review of Automated Pain Assessment in Infants: Features, Classification Tasks, and Databases
Zamzmi, G., Kasturi, R., Goldgof, D. B., Zhi, R., Ashmeade, T. L., & Sun, Y. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2777907 · Cited by 122 · see citing works
Cardiovascular assessment by imaging photoplethysmography – a review
Zaunseder, S., Trumpp, A., Wedekind, D., & Malberg, H. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0119 · Cited by 121 · see citing works
Continuous Monitoring of Vital Signs Using Cameras: A Systematic Review
Vinothini, S., Spicher, N., Wang, J., Ganapathy, N., Warnecke, J. M., Leonhardt, S. K., Swaminathan, R., & Deserno, T. M. (2022) · Sensors · doi:10.3390/s22114097 · Cited by 122 · see citing works
Robust heart rate from fitness videos
Wang, W., Brinker, A. C. D., Stuijk, S., & de Haan, G. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6d02 · Cited by 114 · see citing works
“…enabling non-contact measurement of physiological parameters from a human body, such as heart-rate (Li et al 2014, Tarassenko et al 2014, Kumar et al 2015, Wang et al 2015a, Tulyakov et al 2016), heart-rate variability (Blackford et al 2016), respiration (Tarassenko et al 2014), SpO 2…”
Cho, Y., Julier, S., & Bianchi‐Berthouze, N. (2018) · JMIR Mental Health · doi:10.2196/10140 · Cited by 103 · see citing works
“ntly used [6,7,9]. For this, we used the relative power Signal Quality Index (pSQI), which is to assess the strength of physiological signals in a frequency range of interest, as a measure of quality [11,53,73,74]. The pSQI for the BVP signals can be expressed by: max min Ö Ö Ö min max Ö () ()ÖÖ () f f B total B S f d…”
MethodA Review of Deep Learning-Based Contactless Heart Rate Measurement Methods
Ni, A., Azarang, A., & Kehtarnavaz, N. (2021) · Italian National Conference on Sensors · doi:10.3390/s21113719 · Cited by 84 · see citing works
Experimental Comparison of IR-UWB Radar and FMCW Radar for Vital Signs
Wang, D., Yoo, S., & Cho, S. H. (2020) · Sensors · doi:10.3390/s20226695 · Cited by 101 · see citing works
Khanam, F.-T.-Z., Al‐Naji, A., & Chahl, J. (2019) · Applied Sciences · doi:10.3390/app9204474 · Cited by 95 · see citing works
“Using a monochrome camera, Kumar et al. [96] designed a robust method to extract HR and HRV based on a weighted average and considering di ff erent skin tones, illumination variation, and several motion scenarios.”
MethodRen, L., Kong, L., Foroughian, F., Wang, H., Theilmann, P. T., & Fathy, A. E. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2658567 · Cited by 94 · see citing works
“The HR and RR measurements demonstrated a high level of confidence [36].”
BackgroundNear-Infrared Imaging Photoplethysmography During Driving
Nowara, E. M., Marks, T. K., Mansour, H., & Veeraraghavan, A. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2020.3038317 · Cited by 94 · see citing works
Photonic radar for contactless vital sign detection
Zhang, Z., Liu, Y., Stephens, T., & Eggleton, B. J. (2023) · Nature Photonics · doi:10.1038/s41566-023-01245-6 · Cited by 92 · see citing works
A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos
Wang, C., Pun, T., & Chanel, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00033 · Cited by 91 · see citing works
“…methods Pursche et al. (2012), Stricker et al. (2014), Li et al. (2014), Zaunseder et al. (2014), Muender et al. (2016), Mestha et al. (2014), Kumar et al. (2015), and Moreno et al. (2015) Motion-based methods Balakrishnan et al. (2013), Rubinstein (2013), and Irani et al. (2014) Machine…”
BackgroundMethodInfluentialTelemonitoring systems for respiratory patients: technological aspects
Angelucci, A., & Aliverti, A. (2020) · Pulmonology · doi:10.1016/j.pulmoe.2019.11.006 · Cited by 87 · see citing works
PPGSecure: Biometric Presentation Attack Detection Using Photopletysmograms
Nowara, E. M., Sabharwal, A., & Veeraraghavan, A. (2017) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2017.16 · Cited by 86 · see citing works
“[22], we converted the RGB video to the green channel and we tracked the face using Kanade Lucas Thomasi (KLT) tracker [31].”
BackgroundMethodInfluentialHeartTrack: Convolutional neural network for remote video-based heart rate monitoring
Perepelkina, O. S., Artemyev, M., Churikova, M., & Grinenko, M. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00152 · Cited by 83 · see citing works
“In recent years, there has been emerging a growing number of studies dedicated to remote pulse rate estimation based on data extracted from face videos [3, 4, 5, 6, 7, 8, 9, 10, 1].”
BackgroundMethodHarford, M., Catherall, J., Gerry, S., Young, D., & Watkinson, P. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab1f1d · Cited by 81 · see citing works
“Kumar et al (2015) showed robust HR measurement performance with a monochrome camera (green) and went onto use a multichannel camera in challenging conditions (movement, lighting changes, darker skin colours).”
BackgroundHall, T., Lie, D. Y. C., Nguyen, T. Q., Mayeda, J. C., Lie, P. E., Lopez, J., & Banister, R. E. (2017) · Sensors · doi:10.3390/s17112632 · Cited by 80 · see citing works
Use of smartphone technology in cardiology
Nguyen, H. H., & Silva, J. N. A. (2015) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2015.11.002 · Cited by 79 · see citing works
“Recent studies have validated new algorithms aimed at overcoming these limitations and improve the accuracy of this technology [17].”
BackgroundChaichulee, S., Villarroel, M., Jorge, J., Arteta, C., Green, G., McCormick, K. P., Zisserman, A., & Tarassenko, L. (2017) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2017.41 · Cited by 78 · see citing works
“It should be noted that the non-contact estimation of vital signs is also challenging under low ambient lighting due to low signal-to-noise (SNR) ratios [1, 10].”
BackgroundRemote monitoring of cardiorespiratory signals from a hovering unmanned aerial vehicle
Al‐Naji, A., Perera, A. G., & Chahl, J. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0395-y · Cited by 79 · see citing works
Михайлович, У. А. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabd09 · Cited by 78 · see citing works
“Another important part of ROI refinement is motion compensation (Kumar et al., 2015; Wang et al., 2015).”
BackgroundWang, W., Brinker, A. C. D., & de Haan, G. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2882396 · Cited by 76 · see citing works
Video-based human heart rate measurement using joint blind source separation
Qi, H., Guo, Z., Chen, X., Shen, Z., & Wang, Z. J. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.08.020 · Cited by 75 · see citing works
Smartphone Apps Using Photoplethysmography for Heart Rate Monitoring: Meta-Analysis
Ridder, B. D., Rompaey, B. V., Kampen, J. K., Haine, S. E. F., & Dilles, T. (2018) · JMIR Cardio · doi:10.2196/cardio.8802 · Cited by 73 · see citing works
Face video based touchless blood pressure and heart rate estimation
Jain, M., Deb, S., & Subramanyam, A. V. (2016) · IEEE International Workshop on Multimedia Signal Processing (MMSP) · doi:10.1109/mmsp.2016.7813389 · Cited by 74 · see citing works
“Factors like skin complexion has been overlooked in this study; it is challenging to extract PPG from the face video with a darker skin-tone [10].”
BackgroundMethodRobust blood pressure estimation using an RGB camera
Fan, X., Ye, Q., Yang, X., & Choudhury, S. D. (2018) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-018-1026-6 · Cited by 72 · see citing works
Sun, Z., & Li, X. (2024) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2024.3367910 · Cited by 71 · see citing works
“This spatial coherence in rPPG signals has been leveraged in the design of multiple methodologies, as demonstrated in prior works [27], [28], [29], [50], [51], [52], [53].”
MethodNowara, E. M., McDuff, D., & Veeraraghavan, A. (2021) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv48922.2021.00491 · Cited by 65 · see citing works
“, eyes during blinking and mouth during talking) [30, 14].”
BackgroundRemote photoplethysmography with constrained ICA using periodicity and chrominance constraints
Macwan, R., Benezeth, Y., & Mansouri, A. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0450-3 · Cited by 65 · see citing works
“Furthermore, comparison with smart ROI selection methods such as [17, 19, 20] and [13] was not deemed relevant in order to limit the comparison amongst source separation methods, and the fact that our method can easily be incorporated into an ROI selection framework.”
MethodBounded Kalman filter method for motion-robust, non-contact heart rate estimation.
Prakash, S. K. A., & Tucker, C. S. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.000873 · Cited by 57 · see citing works
Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates
Kim, J. D., Lee, W. H., Lee, Y., Lee, H. J., Cha, T., Kim, S. H., Song, K.-M., Lim, Y., Cho, S. H., Cho, S. H., et al. (2019) · Royal Society Open Science · doi:10.1098/rsos.190149 · Cited by 64 · see citing works
Wital: A COTS WiFi Devices Based Vital Signs Monitoring System Using NLOS Sensing Model
Zhang, X., Gu, Y., Yan, H., Wang, Y., Dong, M., Ota, K., Ren, F., & Ji, Y. (2023) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2023.3264247 · Cited by 60 · see citing works
“However, visionbased solutions [38] are usually susceptible to variations in lighting conditions and present privacy concerns.”
BackgroundNon-contact PPG signal and heart rate estimation with multi-hierarchical convolutional network
Li, B., Zhang, P., Peng, J., & Fu, H. C. (2023) · Pattern Recognition · doi:10.1016/j.patcog.2023.109421 · Cited by 59 · see citing works
“[13] combined HR signals with different ROIs”
ReViSe: Remote Vital Signs Measurement Using Smartphone Camera
Qiao, D., Ayesha, A. H., Zulkernine, F. H., Jaffar, N., & Masroor, R. (2022) · IEEE Access · doi:10.1109/access.2022.3229977 · Cited by 63 · see citing works
Chaichulee, S., Villarroel, M., Jorge, J., Arteta, C., McCormick, K. P., Zisserman, A., & Tarassenko, L. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab525c · Cited by 57 · see citing works
“…signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning ROI was then automatically tracked in consecutive frames using a feature tracker or an image segmentation algo-rithm (Tarassenko et al 2014, Poh et al 2010, 2011, Kumar et al 2015).”
MethodRathore, A. S., Li, Z., Zhu, W., Jin, Z., & Xu, W. (2020) · ACM Computing Surveys · doi:10.1145/3410158 · Cited by 57 · see citing works
“Therefore, the utilization of the camera requires the careful employment of techniques including a weighted average of signals across face regions [85], improved acquisition of light intensity, and precise feature tracking under motion.”
MethodDeep-HR: Fast heart rate estimation from face video under realistic conditions
Sabokrou, M., Pourreza, M., Li, X., Fathy, M., & Zhao, G. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.115596 · Cited by 55 · see citing works
Motion robust PPG-imaging through color channel mapping
Moço, A., Stuijk, S., & de Haan, G. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001737 · Cited by 53 · see citing works
Continuous heart rate measurement from face: A robust rPPG approach with distribution learning
Niu, X., Han, H., Shan, S., & Chen, X. (2017) · IEEE International Joint Conference on Biometrics (IJCB) · doi:10.1109/btas.2017.8272752 · Cited by 51 · see citing works
“In [10], Kumar et al.”
Remote Photoplethysmography With an EEMD-MCCA Method Robust Against Spatially Uneven Illuminations
Song, R., Li, J., Wang, M., Cheng, J., Li, C., & Chen, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3067770 · Cited by 52 · see citing works
“[23] extracted the pulse signals by weighting all candidate rPPG signals with weight coefficients determined from the SNR of pulse extracted on each patch.”
MethodPerson-Specific Heart Rate Estimation With Ultra-Wideband Radar Using Convolutional Neural Networks
Wu, S., Sakamoto, T., Oishi, K., Sato, T., Inoue, K., Fukuda, T., Mizutani, K., & Sakai, H. (2019) · IEEE Access · doi:10.1109/access.2019.2954294 · Cited by 52 · see citing works
Non-Contact Vital Signs Monitoring Through Visible Light Sensing
Abuella, H., & Ekin, S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2960194 · Cited by 52 · see citing works
“system [21]–[24], [27], which uses digital camcorders/cameras with ambient light as the illumination source to measure the measuring changes in light absorption [28].”
BackgroundMotion robust remote photoplethysmography in CIELab color space
Yang, Y., Liu, C., Yu, H., Shao, D.-D., Tsow, F., & Tao, N. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.11.117001 · Cited by 52 · see citing works
“divide the face area into many small regions, and then reduce the body movement-induced artifacts on the rPPG from the entire face area by adjusting the weighting factors for different regions.(15) Since rPPG signals have different amplitudes in the three color channels of RGB color space,(16,17) algorithms based on a…”
BackgroundFouad, R. M., Omer, O. A., & Aly, M. H. (2019) · IEEE Access · doi:10.1109/access.2019.2922304 · Cited by 51 · see citing works
\Accurate measurement of the pulse wave delay with imaging photoplethysmography
Kamshilin, A. A., Sidorov, I. S., Babayan, L., Volynsky, M. A., Giniatullin, R. A., & Mamontov, O. V. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.005138 · Cited by 50 · see citing works
Wei, B., He, X., Zhang, C., & Wu, X. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0300-0 · Cited by 50 · see citing works
“Mayank Kumar also mentioned the similar issue, and introduced a new method for generating high SNR PPG signals from the tracked golden ROIs structured by a weighted average approach [28].”
Huynh, S., Balan, R. K., Ko, J., & Lee, Y. (2019) · ACM Conference on Embedded Networked Sensor Systems (SenSys) · doi:10.1145/3356250.3360036 · Cited by 51 · see citing works
“Prior work has shown that the green channel captured by RGB camera is better than red and blue channels in detecting these colour changes [31, 62].”
BackgroundNon-intrusive Human Vital Sign Detection Using mmWave Sensing Technologies: A Review
Wu, Y., Ni, H., Mao, C., Han, J., & Xu, W. (2023) · ACM Transactions on Sensor Networks · doi:10.1145/3627161 · Cited by 51 · see citing works
“RGB cameras monitor subtle skin color variations due to inconsistent blood volume in arteries and capillaries [34][35].”
BackgroundBlood pressure estimation using video plethysmography
Šećerbegović, A., Bergsland, J., Halvorsen, P. S., Suljanović, N., Mujčić, A., & Balasingham, I. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493307 · Cited by 47 · see citing works
Liu, S., Lan, X., & Yuen, P. C. (2021) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2021.3050060 · Cited by 47 · see citing works
“It is observed that the rPPG signal varies around ± 2 for an RGB24 video when using an entire face as the observation region [42].”
MethodMarcinkevičs, Z., Rubīns, U., Zaharans, J., Miščuks, A., Urtane, E., & Ozoliņa-Moll, L. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.3.035005 · Cited by 46 · see citing works
Illumination variation-resistant video-based heart rate monitoring using LAB color space
Zhang, Y., Dong, Z., Zhang, K., Shu, S., Lu, F., & Chen, J. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106328 · Cited by 45 · see citing works
HRVCam: robust camera-based measurement of heart rate variability
Pai, A., Veeraraghavan, A., & Sabharwal, A. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.2.022707 · Cited by 45 · see citing works
“A peak detection-based algorithm performs poorly in low SNR iPPG signals because it gives rise to false positives that adversely affect HRV estimation.(16) Previous works(7,19) used custom approaches to filter false positives and reduce errors in HRV measurements.”
MethodInfluentialPark, J.-Y., Lee, Y., Choi, Y.-W., Heo, R., Park, H., Cho, S. H., Cho, S. H., & Lim, Y. (2019) · Scientific Reports · doi:10.1038/s41598-019-48386-9 · Cited by 44 · see citing works
Jindal, V. (2016) · IEEE/ACM International Conference on Mobile Software Engineering and Systems (MOBILESoft) · doi:10.1145/2897073.2897132 · Cited by 43 · see citing works
“In our approach, the new PPG signal is obtained using a wearable sensor device like Fitbit or using the mobile phone camera by placing the index finger on the camera lens [2].”
MethodNovel health monitoring method using an RGB camera
Hassan, M., Malik, A. S., David Fofi, B., Saad, M. N. M., & Mériaudeau, F. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.004838 · Cited by 41 · see citing works
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 43 · see citing works
Synthetic Generation of Face Videos with Plethysmograph Physiology
Wang, Z., Ba, Y., Chari, P., Bozkurt, O. D., Brown, G., Patwa, P., Vaddi, N., Jalilian, L., & Kadambi, A. (2022) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52688.2022.01993 · Cited by 41 · see citing works
“Traditional rPPG methods either use Blind Source Separation (BSS) [17, 36, 37] or models based on skin re-flectance [9, 16, 43] to separate out the pulse signal from the color changes on the face.”
MethodA study of color illumination effect on the SNR of rPPG signals
Lin, Y.-C., & Lin, Y. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037807 · Cited by 40 · see citing works
Remote Photoplethysmography: Rarely Considered Factors
Mironenko, Y., Kalinin, K. B., Kopeliovich, M. V., & Petrushan, M. V. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00156 · Cited by 39 · see citing works
“…Four iOS applications for contact and non-contact PPG cICA [37] cICA [37], ICA [28], PCA [29], G [4], CHROM [8], POS [9] SparsePPG [38] DistancePPG [39], CHROM [8], ICA [28] HR-CNN [40] 2SR [35], Li2014 [32], SAMC [30] SynRhythm [41] ICA [28], BCG [31], Li2014 [32], CHROM [8], Niu2017 [42], SAMC…”
MethodKamshilin, A. A., Zaytsev, V. V., Lodygin, A. V., & Кащенко, В. А. (2022) · Scientific Reports · doi:10.1038/s41598-022-05080-7 · Cited by 39 · see citing works
Gupta, A. R., Ravelo-García, A. G., & Morgado‐Dias, F. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106771 · Cited by 38 · see citing works
Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring
Man, P.-K., Cheung, K.-L., Sangsiri, N., Shek, W., Wong, K. L., Chin, J. W., Chan, T. T., & So, R. H. Y. (2022) · Healthcare · doi:10.3390/healthcare10102113 · Cited by 40 · see citing works
Zhang, X., Hu, M., Zhang, Y., Zhai, G., & Zhang, X.-P. S. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200345 · Cited by 37 · see citing works
Liu, Y., Qin, B., Li, R., Li, X., Huang, A., Liu, H., Lv, Y., & Liu, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3060572 · Cited by 38 · see citing works
“…occurred between sequential frames, KLT tracking accuracy on unsolved challenges inherent in the optical flow technique [18], such as large face movement and partial occlusion cases as well as handling textureless facial areas, is not ideal for estimating motion-robust HR for rPPG [16], [17].”
BackgroundPrivacy-Phys: Facial Video-Based Physiological Modification for Privacy Protection
Sun, Z., & Li, X. (2022) · IEEE Signal Processing Letters · doi:10.1109/lsp.2022.3185964 · Cited by 37 · see citing works
“Our method has large perturbation in the cheek and forehead area, which follows the rPPG spatial distribution [38].”
MethodBeat-to-beat heart rate estimation fusing multimodal video and sensor data.
Antink, C. H., Gao, H., Brüser, C., & Leonhardt, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002895 · Cited by 36 · see citing works
“Noise and artifacts might influence channels by varying degrees: While the BCG and the pulse-related head oscillations are very susceptible to motion artifacts, advanced video processing methods allow the extraction of PPG signals even if the subject is moving [10].”
BackgroundYour face your heart: Secure mobile face authentication with photoplethysmograms
Chen, Y.-M., Sun, J., Jin, X., Li, T., Zhang, R., & Zhang, Y.-C. (2017) · IEEE Conference on Computer Communications · doi:10.1109/infocom.2017.8057220 · Cited by 35 · see citing works
“In the literature [16], [18], [19], [25], [26], it is widely accepted that the three channels carry different amount of photoplethysmogram information.”
BackgroundMethodInfluentialPulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality
Kumar, M., Suliburk, J. W., Veeraraghavan, A., & Sabharwal, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-61576-0 · Cited by 36 · see citing works
Park, J.-Y., Cho, H. K., Balan, R. K., & Ko, J. (2020) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3411843 · Cited by 36 · see citing works
“In order to solve such problems, non-contact (remote) PPG schemes have recently been proposed to monitor heart rate variability (HRV) using webcams [53, 56, 73, 115], or the smartphone’s front camera [39, 54].”
Addison, P. S., Jacquel, D., Foo, D. M. H., Antunes, A., & Borg, U. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001989 · Cited by 36 · see citing works
Chen, W., Yi, Z., Lim, L. J. R., Lim, R. Q. R., Zhang, A., Qian, Z., Huang, J., He, J., & Лю, Б. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1420100 · Cited by 39 · see citing works
“Still, the algorithm implemented by this method is complex and time-consuming, and the pulse wave extracted by this method can not see apparent dicrotic waves (Kumar et al., 2015).”
MethodRemote Photoplethysmography for Heart Rate and Blood Oxygenation Measurement: A Review
Pirzada, P., Wilde, A., & Harris‐Birtill, D. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3405414 · Cited by 38 · see citing works
“A pulse oximeter must be physically placed on a finger, which is hard for some patients with incapacities or cognitive challenges [45], [46], [47], during surgery [46], sensitive skin [18], burned skin [46], and in those with severe illness [18] as well as infants [48], [49] and young children [22].”
Camera-based photoplethysmography in an intraoperative setting
Trumpp, A., Lohr, J., Wedekind, D., Schmidt, M. U., Burghardt, M., Heller, A. R., Malberg, H., & Zaunseder, S. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0467-7 · Cited by 34 · see citing works
Remote Heart Rate Measurement from RGB-NIR Video Based on Spatial and Spectral Face Patch Selection
Kado, S., Monno, Y., Moriwaki, K., 吉崎和徳, Tanaka, M., & Okutomi, M. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513464 · Cited by 34 · see citing works
Detail-preserving pulse wave extraction from facial videos using consumer-level camera
Wang, D., Yang, X., Liu, X., Jin, J., & Fang, S. (2020) · Biomedical Optics Express · doi:10.1364/boe.380646 · Cited by 34 · see citing works
Color-Distortion Filtering for Remote Photoplethysmography
Wang, W., Brinker, A. C. D., Stuijk, S., & de Haan, G. (2017) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2017.18 · Cited by 34 · see citing works
“, G [1], [13], [14], GR [15], HUE [11], PCA [4], ICA [5], CHROM [7], [16], [17], PBV [8], and POS [9].”
Video pulse rate variability analysis in stationary and motion conditions
Rodríguez, A., & Ramos-Castro, J. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0437-0 · Cited by 34 · see citing works
“[24] performed the acquisition of signals in three natural motion scenarios.”
BackgroundMethodInfluential
- Authors
- Kumar, M., Veeraraghavan, A., & Sabharwal, A.
- Affiliations
- Rice University (US)
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-04-06
- Volume
- 6
- Issue
- 5
- Pages
- 1565
- ISSN
- 2156-7085 (ISSN-L)
- PMC
- PMC4467696
- OpenAlex
- W2029745771
- Cited by
- 417
- References
- 17
- Citations by year
- 2026: 9 · 2025: 21 · 2024: 36 · 2023: 46 · 2022: 49 · 2021: 57 · 2020: 35 · 2019: 47 · 2018: 46 · 2017: 33 · 2016: 31 · 2015: 7
- FWCI
- 19.38
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Biomedical Optics Express (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Rice Research Repository (Rice University) (submittedVersion)
- Funders
- National Science Foundation (NSF) (1126478, 1429047)
- Texas Higher Education Coordinating Board (THECB) (THECB-NHARP 13308)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- respiratory rate estimation, photoplethysmography, skin color change, blood perfusion, incident light intensity, signal-to-noise ratio, darker skin tones, motion robustness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review