Optimal placement of DSTATCOM in distribution network based on load flow and voltage stability indices studies
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The power utilities are experiencing a new challenge as the demand for electrical power is increasing on a regular basis. This forced the existing networks operates closed to its stability limits. The ability of a power system to remain acceptable magnitude voltages at all bus under both normal and contingency conditions, known as voltage stability is the major concern for both transmission and distribution network to ensure that a secure and reliable electrical power is able to transmit from generation to load side. This can be mitigated by integrating Custom Power (CP) device on the existing transmission system. However, the location of CP device is significantly important to ensure adequate investment of CP device in networks that will enhance the voltage stability margin, reduce power loss and improve voltage profile. In this paper, the optimal location of Distribution Static Synchronous Compensator (DSTATCOM) is introduced by analyzing results obtained from two studies; load flow and voltage stability indices. The studies were examined using the modified IEEE 30 bus system which is modelled and tested using DigSILENT PowerFactory 16 as simulation tools.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was confirmed that the proposed control scheme increased output voltage amplitude while offering a superior transient response and precise phase positioning for various load conditions.”
From A Comprehensive Review on the Role of Artificial Intelligence in Power System Stability, Control, and Protection: Insights and Future Directions (2024) · cites this paper as [105]
Citations
Cites
Musirin, I., & Abdul Rahman, T. K. (2003) · Student Conference on Research and Development · doi:10.1109/scored.2002.1033108 · Cited by 307 · cited 7×
“The procedures to evaluate maximum loadability for strong and weak bus identification are determined as follows [10]:”
BackgroundMethodInfluentialDSTATCOM allocation in distribution networks considering load variations using bat algorithm
Yuvaraj, T., Ravi, K., & Devabalaji, K. R. (2017) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.08.006 · Cited by 224
Real-time contingency evaluation and ranking technique
Moghavvemi, M., & Faruque, O. (1998) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19982179 · Cited by 184 · cited 3×
“Voltage Collapse Proximity Indicator (VCPI) derived by Moghavvemi and Faruque (1998) in [11], using the maximum power transferred trough a single line concept.”
MethodInfluentialSirjani, R., & Jordehi, A. R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.035 · Cited by 152 · cited 1×
“Both of the FACTS and CP devices have the same common technical base but different performance goals since FACTS devices are used in transmission system whereas CP devices are used in distribution system [4].”
BackgroundLine collapse proximity index for prediction of voltage collapse in power systems
Tiwari, R., Niazi, K. R., & Gupta, V. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.03.022 · Cited by 122 · cited 2×
“…more suitable to indicate the voltage collapse in the line. c) Line Collapse Proximity Index (LCPI) The Line Collapse Proximity Index proposed by Tiwari et al (2012) in [12] has improved the limitation in other indices by including the line charging reactance in the equations of indices and the…”
BackgroundImpact of distributed generators on the power loss and voltage profile of sub-transmission network
Ogunjuyigbe, A. S. O., Ayodele, T. R., & Akinola, O. O. (2016) · Journal of Electrical Systems and Information Technology · doi:10.1016/j.jesit.2015.11.010 · Cited by 90
ASEAN Plan of Action For Energy Cooperation(APAEC) 2004-2009
Jiranuntarat, S. (2007) · 한국국제정치학회 학술대회 발표논문집 · Cited by 37
Essential aspects of power system planning in developing countries
Al‐Shaalan, A. M. (2011) · Journal of King Saud University - Engineering Sciences · doi:10.1016/j.jksues.2009.12.002 · Cited by 21
Chabok, B. S., & Ashouri, A. (2016) · American journal of electrical and electronic engineering · doi:10.12691/ajeee-4-2-1 · Cited by 19 · cited 1×
“The investigation on the optimal placement of DSTATCOM for voltage stability improvement are done in [7 – 8].”
MethodComparative analysis of custom power devices for power quality improvement in non-linear loads
Saggu, T. S., & Singh, L. (2015) · International Conference on Recent Advances in Engineering & Computational Sciences · doi:10.1109/raecs.2015.7453421 · Cited by 16 · cited 1×
“DSTATCOM is not only capable to balance the current, but also remove harmonics from the current and regulate the load voltage which significantly improve the power factor [3].”
Background
Research works printed but not linked: 1
- kailay, 2016, FACTS Based Power System Optimization by Using Newton Raphson Technique, International Journal of Emerging Research in Management, 5, 1
Cited by
Alhamrouni, I., Abdul Kahar, N. H., Salem, M., Swadi, M., Zahroui, Y., Kadhim, D. J., Mohamed, F. A., & Alhuyi Nazari, M. (2024) · Applied Sciences · doi:10.3390/app14146214 · Cited by 217
“For uninterruptible power supply (UPS) systems, Ismail et al. [105] proposed a modified algorithm of pulse width modulation (PWM) inverter deadbeat control.”
MethodSelf-citationIsmail, B., Wahab, N. I. A., Othman, M. L., Radzi, M. A. M., Naidu, K., & Naain, M. M. (2020) · IEEE Access · doi:10.1109/access.2020.3043297 · Cited by 153
“in [126] for solving optimal location of DSTATCOM in distribution network for voltage stability improvement, voltage profile enhancement and power loss reduction.”
BackgroundSelf-citationIsmail, B., Wahab, N. I. A., Othman, M. L., Radzi, M. A. M., Vijayakumar, K. N., Rahmat, M. K., & Naain, M. M. (2022) · IEEE Access · doi:10.1109/access.2022.3204792 · Cited by 56
“Due to location wise, line 27-30, 27-29 and 25-26 have always been highlighted in the literature [46], [47], [48], [49], [50], [51] as the weakest lines for this network due to its distant location.”
BackgroundSelf-citationVoltage stability improvement in distribution networks by using soft open points
Mardanimajd, K., Karimi, S., & Anvari‐Moghaddam, A. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109582 · Cited by 49
Improvement of the performance of STATCOM in terms of voltage profile using ANN controller
Alatshan, M. S., Alhamrouni, I., Sutikno, T., & Jusoh, A. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v11.i4.pp1966-1978 · Cited by 15
“It should be noted that a great improvement was obtained in the weakest bus 14 where the STATCOM was placed [29].”
BackgroundSelf-citationMulti-input interleaved DC-DC converter for hybrid renewable energy applications
Alhamrouni, I., Salem, M., Zahraoui, Y., Ismail, B., Jusoh, A., & Sutikno, T. (2022) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v11i3.3779 · Cited by 14
“However, the intermittency of renewable energy produced less efficient energy than non-renewable energy due to weather dependency [9], [10].”
Self-citationAnalytical Approaches on Optimal Placement of STATCOM Under Contingency Occasions
Ismail, B., Wahab, N. I. A., Othman, M. L., Radzi, M. A. M., Vijayakumar, K. N., & Naain, M. M. (2020) · International Conference on Smart Power & Internet Energy Systems (SPIES) · doi:10.1109/spies48661.2020.9243128 · Cited by 13
Self-citationStudy of Different ANN Algorithms for Voltage Stability Analysis
Aydın, F., & Gümüş, B. (2020) · Innovations in Intelligent Systems and Applications Conference (ASYU) · doi:10.1109/asyu50717.2020.9259817 · Cited by 11
“V i and V j are the voltage magnitudes at bus i and j [24].”
BackgroundOptimal Placement and Sizing of STATCOM(s) for Power System Security Improvement using MOPSO
Ismail, B., Wahab, N. I. A., Othman, M. L., Radzi, M. A. M., Kahar, N. H. A., & Awalin, L. J. (2022) · IEEE International Conference on Power and Energy · doi:10.1109/pecon54459.2022.9988946 · Cited by 6
“Moreover, these lines have been highlighted as one of the critical lines in IEEE 30 networks according to the literature [11-15].”
BackgroundSelf-citationIntegration of STATCOM and ESS for power system stability improvement
Alhamrouni, I., Ismail, R., Salem, M., Ismail, B., Jusoh, A., & Sutikno, T. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v11.i2.pp859-869 · Cited by 6
Self-citationAlhamrouni, I., Salem, M., Jusoh, A., & Sutikno, T. (2022) · TELKOMNIKA (Telecommunication Computing Electronics and Control) · doi:10.12928/telkomnika.v20i5.24292 · Cited by 5
Self-citationOPTIMAL PLACEMENT AND SIZING OF DG and D-STATCOM IN A DISTRIBUTION SYSTEM: A REVIEW
Veeraganti, S. D., & Mohamed Imran, A. (2022) · International Virtual Conference on Power Engineering Computing and Control: Developments in Electric Vehicles and Energy Sector for Sustainable Future (PECCON) · doi:10.1109/peccon55017.2022.9851016 · Cited by 4
Almelian, M. M., Mohd, I. I., Aker, E. E., Omran, M. A., Salem, M., Ahmad, A. Z., & Albishti, A. A. (2024) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v15.i3.pp1478-1489 · Cited by 1
“The modulation of the amplitude of VSC output voltage (Vc) regulates the exchange of reactive power between STATCOM and the system [15], [16].”
Background(2020) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v10i4.11434.g8075 · Cited by 1
“Distribution algorithm used for the demand side management[66].”
MethodCourteau, G., Aurberson, E., Favre‐Perrod, P., Marignac, O. D., Bozorg, M., & Carpita, M. (2022) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam53979.2022.9842206 · Cited by 1
(2023) · International Research Journal of Modernization in Engineering Technology and Science · doi:10.56726/irjmets43529
Metadata
- Authors
- Ismail, B., Naain, M. M., Wahab, N. I. A., Awalin, L. J., Alhamrouni, I., & Rahim, M. F. A.
- Affiliations
- Universiti Putra Malaysia (MY)
- University of Kuala Lumpur (MY)
- ORCID
- Venue
- 2017 International Conference on Engineering Technology and Technopreneurship (ICE2T)
- Publisher
- IEEE
- Published
- 2017-09
- Pages
- 1-6
- OpenAlex
- W2774099539
- Cited by
- 15
- References
- 15
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 6 · 2020: 6
- FWCI
- 2.32
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Engineering Technology and Technopreneurship (ICE2T) (publishedVersion)
- Universiti Putra Malaysia Institutional Repository (Universiti Putra Malaysia) (acceptedVersion)
- Funders
- Ministry of Higher Education, Malaysia
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- DSTATCOM, optimal placement, distribution networks, voltage stability, power flow analysis, voltage stability index, power loss reduction, voltage profile, custom power devices, IEEE 30-bus system
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.