CoChat

Non-contact Doppler radar based prediction of nocturnal body orientations using deep neural network for chronic heart failure patients

Open access
Tran, Vinh Phuc, Al-Jumaily, Adel Ali · 2017 · 2017 International Conference on Electrical and Computing Technologies and Applications (ICECTA)

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Sleep is crucial in our daily life as it plays a key role in our physical and mental health. It is important to monitor the sleep body orientations and movements due to its relationships to particular diseases, e.g., obstructive sleep apnea, insomnia or periodic limb movement disorder. Analyzing sleep body orientations also helps in determining sleep quality and irregular sleeping patterns. However, the current non-invasive sleep body orientations monitoring technologies are not well suited for long-term continuous monitoring due to its restrictions in mobility and comfort. This paper proposes a system that applies a features extraction process, utilizing wavelet packet decomposition, to extract features that describe the non-contact Doppler radar signatures caused by the body orientations. A database consisting of 24 chronic heart failure patients is selected for the training, validation and test of the non-contact body orientations prediction. These patients are diagnosed with New York Heart Association heart failure classification Class II & III and underwent full polysomnography analysis for the diagnosis of sleep apnea, disordered sleep, or both. The patients' data are randomly concatenated and partitioned into the ratio of 50% for `Training', 15% for `Validation' and 35% for `Test. Across the `Test dataset with total sleep duration of 65 hours, the body orientations prediction accuracy achieved a correct classification rate of 99.2% for 5 classes of `Prone', `Upright', `Supine', `Right and `Left body orientations. The misclassification rate is 0.8%. A potential application would be non-contact continuous monitoring of nocturnal body orientations in the home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/icecta.2017.8252020

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 16

Metadata

Authors
Tran, V. P., & Al-Jumaily, A. A.
Affiliations
University of Technology Sydney (AU)
Venue
2017 International Conference on Electrical and Computing Technologies and Applications (ICECTA)
Publisher
IEEE
Published
2017-11
Pages
1-5
OpenAlex
W2784051633
Cited by
15
References
4
Citations by year
2025: 1 · 2024: 3 · 2023: 5 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 2
FWCI
1.63
Type
conference paper
Language
en
Open access
Licence
other-oa
Locations
  • International Conference on Electrical and Computing Technologies and Applications (ICECTA) (publishedVersion)
  • UTS ePRESS (University of Technology Sydney) (submittedVersion, other-oa)
Funders
  • Australian Government
  • ResMed
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
Keywords
chronic heart failure, sleep apnea, wavelet packet decomposition, deep neural network, polysomnography, home sleep monitoring, long-term continuous monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-contact Doppler radar based prediction of nocturnal body orientations using deep neural network for chronic heart failure patients. https://app.cochat.ai/papers/10.1109/icecta.2017.8252020
The paper
Tran, V. P., & Al-Jumaily, A. A. (2017). Non-contact Doppler radar based prediction of nocturnal body orientations using deep neural network for chronic heart failure patients. 2017 International Conference on Electrical and Computing Technologies and Applications (ICECTA). https://doi.org/10.1109/icecta.2017.8252020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.