Abstract
This paper deals with multiple insulated gate bipolar transistor (IGBTs) open circuit faults detection and localization in a pulse width modulation (PWM) voltage source inverter (VSI) fed induction motor based on a modified slope method. Firstly, a detection algorithm was used to calculate the slope of the current-vector trajectory in complex plan αβ. This algorithm detects the faulty bridge. Second, the Schmitt-trigger is used for the phase's currents monitoring. This circuit determines the phase's currents polarity and detect whether the current in the faulty arm is positive or negative. The analysis of two combined information makes it possible to diagnose the two simultaneous IGBTs open circuit fault within inverter. The proposed technique is developed and implemented to vector control induction motor drives. An experimental setup in the laboratory is used to compare the simulation results and the experimental results and to evaluate the performances of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“The localization of the faulty switch can also be performed by the analysis of the current space vector trajectory diameter [14]-[15].”
MethodA New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Signal processing methods using motor currents like average current method [10]–[12] and current slope analysis [13], [14] have the advantage that they are free of machine or inverter models and load transients.”
MethodOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
Metadata
- Authors
- Trabelsi, M., Boussak, M., & Gossa, M.
- Venue
- The XIX International Conference on Electrical Machines - ICEM 2010
- Publisher
- IEEE
- Published
- 2010-09
- Pages
- 1-6
- OpenAlex
- W2035336908
- Cited by
- 94
- References
- 0
- FWCI
- 7.42
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple IGBTs open circuit faults diagnosis in voltage source inverter fed induction motor using modified slope method. https://app.cochat.ai/papers/10.1109/icelmach.2010.5608044
- The paper
- Trabelsi, M., Boussak, M., & Gossa, M. (2010). Multiple IGBTs open circuit faults diagnosis in voltage source inverter fed induction motor using modified slope method. The XIX International Conference on Electrical Machines - ICEM 2010. https://doi.org/10.1109/icelmach.2010.5608044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.