Grid connected wind driven permanent magnet synchronous generator with high frequency solid state transformer
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents the control of grid connected wind driven permanent magnet synchronous generator through solid state transformer with a high frequency multistage converter interconnect. Maximum power point tracking is carried out in the high frequency generator side converter stage where as the grid side converter takes care of the synchronization. The model parameters for the high frequency transformer are obtained by analytical calculation and the same is used in the simulation. A push pull converter with incremental conductance algorithm on the generator side tracks the MPP. It also converts the dc output into high frequency wave so that it can be directly applied to the primary of the high frequency transformer. The rectified secondary voltage is grid synchronized through the grid side inverter with synchronous reference controller. The entire system including the high frequency transformer is simulated in MATLAB/Simulink for a 2.5 kW PMSG.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This topology is used for the high power application; because the DAB topology can realize zero-voltage switching of power devices while minimizing the loss caused by the hard switching in the circuit [125].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [125]
Citations
Cites
Power Electronics Converters for Wind Turbine Systems
Blaabjerg, F., Liserre, M., & Ma, K. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2181290 · Cited by 918
Fundamental and Advanced Topics in Wind Power
Carriveau, R. (2011) · InTech eBooks · doi:10.5772/731 · Cited by 146
Wind Turbine Control and Monitoring
Luo, N., Vidal, Y., & Acho, L. (2014) · Advances in industrial control · doi:10.1007/978-3-319-08413-8 · Cited by 133
Solid state transformer in the future smart electrical system
She, X., & Huang, A. (2013) · 2013 IEEE Power & Energy Society General Meeting · doi:10.1109/pesmg.2013.6672768 · Cited by 81
Yu, K. N., & Liao, C.-K. (2015) · Journal of Applied Research and Technology · doi:10.1016/j.jart.2015.06.002 · Cited by 69
Vijayakumari, A., Devarajan, A. T., & Devarajan, N. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.015 · Cited by 39
Self-citationRaza, K. S. M., Goto, H., Guo, H., & Ichinokura, O. (2008) · IEEE International Conference on Sustainable Energy Technologies · doi:10.1109/icset.2008.4747083 · Cited by 34
MPPT control for a PMSG-based grid-tied wind generation system
Wang, X., Yuvarajan, S., & Fan, L. (2010) · North American Power Symposium (NAPS) · doi:10.1109/naps.2010.5619585 · Cited by 31
Topologies and control of grid connected power converters
Vijayakumari, A., Warrier, B. R., & Devarajan, N. (2014) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct.2014.7054896 · Cited by 21
Self-citationGrid-connected topology of PMSG wind power system based on VSC-HVDC
Zhao, K., Li, G., Wang, B., & Zhou, M. Q. (2011) · IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies · doi:10.1109/drpt.2011.5993906 · Cited by 12
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Solid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
Deepak, S., & Mohanrajan, S. R. (2022) · IEEE International Conference on Recent Advances and Innovations in Engineering (ICRAIE) · doi:10.1109/icraie56454.2022.10054344 · Cited by 10
Virtual inertia control for transient active power support from DFIG based wind electric system
Deepak, C. M., Vijayakumari, A., & Mohanrajan, S. R. (2017) · IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology · doi:10.1109/rteict.2017.8256710 · Cited by 8
Self-citationComparsion Study of Conventional, & Improved Perturb and Observe to Charge an EV Battery
Jayakumar, M., & KAMLAGAR, R. (2023) · Innovations in Power and Advanced Computing Technologies (i-PACT) · doi:10.1109/i-pact58649.2023.10434830 · Cited by 2
Metadata
- Authors
- Sandeep, P. V., & Vijayakumari, A.
- Affiliations
- Amrita Vishwa Vidyapeetham (IN)
- ORCID
- Vijayakumari, A.
- Venue
- 2016 International Conference on Emerging Technological Trends (ICETT)
- Publisher
- IEEE
- Published
- 2016-10
- Pages
- 1-6
- OpenAlex
- W2593746383
- Cited by
- 6
- References
- 14
- Citations by year
- 2023: 1 · 2022: 1 · 2020: 1 · 2018: 2 · 2017: 1
- FWCI
- 1.41
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Emerging Technological Trends (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Photovoltaic System Optimization Techniques
- Keywords
- permanent magnet synchronous generator, wind energy conversion, grid-connected inverter, multistage converter, maximum power point tracking, push-pull converter, incremental conductance, synchronous reference frame control, transformer parameter estimation, grid synchronization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.