Cited by 9Cloud Computing and Resource ManagementEnergy Efficiency in ComputingSoftware-Defined Networks and 5G

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Optimal VM Placement Approach Using Fuzzy Reinforcement Learning for Cloud Data Centers

Jumnal, Anand, Dilip Kumar, S M·2021·2021 Third International Conference on Intelligent Communication Technologies and Virtual Mobile Networks (ICICV)

Abstract

Ineffective resource management in cloud data centers leads to high energy usage and cost to maintain the resources. A Virtual machine (VM) placement is a part of the VM consolidation problem where each VM should be mapped to the available host. An optimal VM placement is an effective way to enhance both resource usage and energy efficiency. However, minimizing the energy consumption without affecting SLA violation and performance of the application is quite challenging. This paper proposes a fuzzy based State-Action-Reward-State-Action (SARSA) reinforcement learning algorithm to address the VM placement problem. The integration of fuzzy controller with Reinforcement learning (RL) algorithm is capable of optimizing the reallocation of maximal number of VMs into a minimal number of hosts that reduce energy usage and wastage of resource as well. The proposed work is capable of handling the fluctuating workload situations and delivers proper placement of VMs (initial or re-mapping) while ensuring the desired Quality-of-Service (QoS) demands of users to meet the Service Level Agreement (SLA). The experimental results exhibit reduced consumption of energy and less resource wastage as compared with other VM placement algorithms.

Overview

Integrity signals

Registry

Crossref · 10.1109/icicv50876.2021.9388424

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 1

  1. 2016, Cloudsim

Cited by

Sorted by citations

See all 9

Metadata

Authors
Jumnal, A., & Dilip Kumar, S. M.
Venue
2021 Third International Conference on Intelligent Communication Technologies and Virtual Mobile Networks (ICICV)
Publisher
IEEE
Published
2021-02-04
Pages
29-35
OpenAlex
W3147611418
Cited by
9
References
17
Citations by year
2025: 2 · 2024: 2 · 2023: 2 · 2022: 3
FWCI
1.45
Type
conference paper
Language
en
Open access
closed
Locations
International Conference on Intelligent Communication Technologies and Virtual Mobile Networks (ICICV) (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
  • Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
  • Physical Sciences › Computer Science › Computer Networks and Communications › Software-Defined Networks and 5G
Keywords
virtual machine placement, fuzzy reinforcement learning, SARSA algorithm, cloud data centers, energy efficiency, VM consolidation, resource management, service level agreements, quality of service, workload fluctuation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review