A Wearable Acceleration Sensor System for Gait Recognition
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper addresses the problem of human recognition based on their gait acceleration signal characteristics produced by walking. A portable microprocessor-based data collection device was designed to measure the three-dimensional gait acceleration signals during human walking. The system consists of a tri-axial accelerometer, a MCU, 32 M bytes of RAM, and a data transfer module for data transfer. The device was fixed to the user's waist and three-dimensional acceleration signals were recorded at a sampling rate of 250 Hz. After completing the recording, data stored in the RAM were transferred to a personal computer for wavelet denoising, gait cycles dividing, and gait pattern extracting. Through the analysis in time domain and frequency domain, and using dynamic time warping to deal with the problems result from naturally occurring changes in walking speed, 1-nearest neighbor is used for individual identification. Experiments were performed on 21 subjects walking on their normal speed. The methods of gait analysis in time domain and frequency domain are applying, the equal error rate of 5.6% and 21.1% are achieved respectively. Our preliminary results indicate that it is possible to recognize users based on their gait acceleration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The humanID gait challenge problem: data sets, performance, and analysis
Sarkar, S., Phillips, P. J., Liu, Z., Vega, I. R., Grother, P., & Bowyer, K. W. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.39 · Cited by 1,133
Cited by
Inertial Sensor-Based Gait Recognition: A Review
Sprager, S., & Juric, M. (2015) · Sensors · doi:10.3390/s150922089 · Cited by 347
Unobtrusive User-Authentication on Mobile Phones Using Biometric Gait Recognition
Derawi, M. O., Nickel, C., Bours, P., & Busch, C. (2010) · 2010 Sixth International Conference on Intelligent Information Hiding and Multimedia Signal Processing · doi:10.1109/iihmsp.2010.83 · Cited by 343
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2020) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2020.2985628 · Cited by 305
Deep Learning-Based Gait Recognition Using Smartphones in the Wild
Zou, Q., Wang, Y., Wang, Q., Zhao, Y., & Li, Q. (2018) · arXiv · doi:10.48550/arxiv.1811.00338 · Cited by 305
(2019) · ACM Computing Surveys · doi:10.1145/3230633 · Cited by 303
“In Reference [46], a portable microprocessor-based data acquisition device was developed for measuring the three-dimensional gait acceleration signals during human walking.”
Method
Metadata
- Authors
- Rong, L., Jianzhong, Z., Ming, L., & Xiangfeng, H.
- Venue
- 2007 2nd IEEE Conference on Industrial Electronics and Applications
- Publisher
- IEEE
- Published
- 2007-05
- Pages
- 2654-2659
- OpenAlex
- W1986553199
- Cited by
- 146
- References
- 1
- FWCI
- 9.96
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wearable Acceleration Sensor System for Gait Recognition. https://app.cochat.ai/papers/10.1109/iciea.2007.4318894
- The paper
- Rong, L., Jianzhong, Z., Ming, L., & Xiangfeng, H. (2007). A Wearable Acceleration Sensor System for Gait Recognition. 2007 2nd IEEE Conference on Industrial Electronics and Applications. https://doi.org/10.1109/iciea.2007.4318894
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.