Enabling winter behavior analysis on electrically heated residential buildings by smart sub-metering
Abstract
Load monitoring emerges in the smart grids context as an important part of the backbone of management systems. A variety of new products are offered by markets adding a certain level of intelligence in load monitoring systems, many of them focusing households to verify and in some cases regulate their own consumption. However, those systems even if they are affordable, some technical lacks are present limiting their utilization in research and development activities, e.g. the accuracy, completeness, consistency, and timeliness of information. Focusing in that, this paper proposes a sub-metering prototype system that fits well for the research and development activities for residential buildings in the smart grid context. Details of the system design and experimental results are provided which confirm the validity of the proposition.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Heat loss coefficients and time constants used in the simulation of the park of buildings correspond to typical values for Canadian detached houses, as confirmed by field measurements [14,33,34].
“The heat loss coefficients and time constants used in the simulation of the park of buildings correspond to typical values for Canadian detached houses as confirmed by field measurements reported in [14,33,34] and illustrated by Figure 3.”
From EV Overnight Charging Strategy in Residential Sector: Case of Winter Season in Quebec (2021) · cites this paper as [14]
The framework integrates probabilistic models based on measurements of occupied houses in Quebec and thermal models from the real-time emulation system proposed in [14,33].
“It is to be noticed that the studied scenarios are focused on assessing a mostly cold environment, so the framework integrates probabilistic models based on measurements of occupied houses in the Quebec province and thermal models from the real-time emulation system proposed in [14,33].”
From EV Overnight Charging Strategy in Residential Sector: Case of Winter Season in Quebec (2021) · cites this paper as [14]
Cited by
Sorted by citations
EV Overnight Charging Strategy in Residential Sector: Case of Winter Season in Quebec
Cardenas, A., Guzman, C., & Martinez, W. (2021) · Vehicles · doi:10.3390/vehicles3030034 · Cited by 19 · see citing works
“Heat loss coefficients and time constants distribution for the emulated park of residential buildings (from [14,33,34]).”
BackgroundMethodSelf-citation
- Authors
- Guzman, C., Rueda, L., Romero, G., Biscans, S., Agbossou, K., & Cardenas, A.
- Affiliations
- Université du Québec à Trois-Rivières (CA)
- Venue
- 2018 IEEE International Conference on Industrial Technology (ICIT)
- Publisher
- IEEE
- Published
- 2018-02
- Pages
- 1213-1218
- OpenAlex
- W2798676575
- Cited by
- 12
- References
- 0
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 3 · 2019: 4 · 2018: 3
- FWCI
- 4.39
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Conference on Industrial Technology (ICIT) (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › IoT-based Smart Home Systems
- Keywords
- residential buildings, electric heating, load monitoring, smart grid, household energy consumption
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review