Evaluation of the Bremen SSVEP based BCI in real world conditions
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) provides the possibility to translate brain neural activity patterns into control commands without user's movement. The brain activity is most commonly measured non-invasively via standard electroencephalography (EEG), i.e., with electrodes placed on the surface of the scalp. In this article, we evaluate a BCI system based on steady-state visual evoked potentials (SSVEPs) in real world conditions. Although the performance of this type of BCI has already been proved by several research groups with healthy users in laboratory settings assisted by scientific researchers, there are still many difficulties in changing from demonstration systems to practical BCIs. The Bremen-BCI was evaluated in this case study with 37 naive subjects (without any SSVEP-BCI experience), including 8 handicapped users, at the international rehabilitation fair RehaCare2008. In spite of unsuitable environment conditions on the fair, the spelling tasks were successfully completed by 32 participants with a mean accuracy of over 92% and an average information transfer rate (ITR) of 22.6[bits/min]. No significant dependency of the physical disability of participants on the ITR could be observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“de Brain-Computer Interfaces and are described as very reliable in the literature [9]–[11].”
BackgroundBreaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722
How many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423 · cited 1×
“Although the performance of this type of BCI has already been evaluated by many research groups through a variety of laboratory demonstrations, researchers are still facing many difficulties in changing from demonstration systems to practically applicable systems [14].”
BackgroundThe Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338 · cited 1×
“In the study presented in [27], only 8 out of 14 healthy BCI novices could perform at more than 84% accuracy in their first BCI session.”
Background
Cited by
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Self-citationBCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Self-citationBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“Additionally, after classification of a nonzero class, the data window was cleared [23] and an idle period, in which no further classification will be made, of 1 s is introduced.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Volosyak, I., Cecotti, H., Valbuena, D., & Graser, A.
- Venue
- 2009 IEEE International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 322-331
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2114029315
- Cited by
- 74
- References
- 5
- FWCI
- 12.40
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.