Proportional EMG control of ankle plantar flexion in a powered transtibial prosthesis
Open accessThe DOI matches its Crossref record.
Abstract
The human calf muscle generates 80% of the mechanical work to walk throughout stance-phase, powered plantar flexion. Powered plantar flexion is not only important for walking energetics, but also to minimize the impact on the leading leg at heel-strike. For unilateral transtibial amputees, it has recently been shown that knee load on the leading, intact limb decreases as powered plantar flexion in the trailing prosthetic ankle increases. Not surprisingly, excessive loads on the leading, intact knee are believed to be causative of knee osteoarthritis, a leading secondary impairment in lower-extremity amputees. In this study, we hypothesize that a transtibial amputee can learn how to control a powered ankle-foot prosthesis using a volitional electromyographic (EMG) control to directly modulate ankle powered plantar flexion. We here present preliminary data, and find that an amputee participant is able to modulate toe-off angle, net ankle work and peak power across a broad range of walking speeds by volitionally modulating calf EMG activity. The modulation of these key gait parameters is shown to be comparable to the dynamical response of the same powered prosthesis controlled intrinsically (No EMG), suggesting that transtibial amputees can achieve an adequate level of powered plantar flexion controllability using direct volitional EMG control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- 10.1080/00222895.1983.10735302 · DOI · Paper page
- 10.1109/TRO.2008.2008747 · DOI · Paper page
- 10.1109/TBME.1980.326652 · DOI · Paper page
- 10.1097/00003086-198305000-00021 · DOI · Paper page
- kuo, 2002, Energetics of actively powered locomotion using the simplest walking model, J Biomech Eng, 124, 113, 10.1115/1.1427703 · DOI · Paper page
- 10.1109/IEMBS.2007.4352965 · DOI · Paper page
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 10.1186/1743-0003-4-48 · DOI
- 10.1016/j.gaitpost.2011.07.001 · DOI · Paper page
- 10.1016/j.apmr.2004.04.034 · DOI · Paper page
- 10.1242/jeb.044214 · DOI
- 10.1098/rspb.2011.1194 · DOI · Paper page
- 10.1242/jeb.017269 · DOI · Paper page
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Fleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
“Wang et al [28] GAS (unspecified head) Low-pass filtered (15 Hz), rectified envelope (200 ms moving average window) Plantar flexor torque gain (push-off only) Transtibial Level-ground walking”
BackgroundInfluentialNext-generation wearable electronics
Cima, M. J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2952 · Cited by 173
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Metadata
- Authors
- Wang, J., Kannape, O. A., & Herr, H. M.
- Venue
- 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR)
- Publisher
- IEEE
- Published
- 2013-06
- Volume
- 2013
- Pages
- 1-5
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2059530986
- Cited by
- 67
- References
- 0
- FWCI
- 11.88
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proportional EMG control of ankle plantar flexion in a powered transtibial prosthesis. https://app.cochat.ai/papers/10.1109/icorr.2013.6650391
- The paper
- Wang, J., Kannape, O. A., & Herr, H. M. (2013). Proportional EMG control of ankle plantar flexion in a powered transtibial prosthesis. 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR). https://doi.org/10.1109/icorr.2013.6650391
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.