CoChat

A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation

Open access
Delph, Michael A., Fischer, Sarah A., Gauthier, Phillip W., Luna, Carlos H. Martinez, Clancy, Edward A., Fischer, Gregory S. · 2013 · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR)
Cited by 119

The DOI matches its Crossref record.

Abstract

Stroke affects 750,000 people annually, and 80% of stroke survivors are left with weakened limbs and hands. Repetitive hand movement is often used as a rehabilitation technique in order to regain hand movement and strength. In order to facilitate this rehabilitation, a robotic glove was designed to aid in the movement and coordination of gripping exercises. This glove utilizes a cable system to open and close a patients hand. The cables are actuated by servomotors, mounted in a backpack weighing 13.2 lbs including battery power sources. The glove can be controlled in terms of finger position and grip force through switch interface, software program, or surface myoelectric (sEMG) signal. The primary control modes of the system provide: active assistance, active resistance and a preprogrammed mode. This project developed a working prototype of the rehabilitative robotic glove which actuates the fingers over a full range of motion across one degree-of-freedom, and is capable of generating a maximum 15N grip force.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/icorr.2013.6650426

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. 10.1016/S1050-6411(01)00033-5 · DOI · Paper page
  2. 10.1109/IEMBS.2009.5333630 · DOI
  3. salini, 2003, Design of instrumentation for recording the electromyogram, Independent Study Project Department of Electrical and Computer Engineering Worcester Polytechnic Institute
  4. brassil, 2002, Hand Rehabilition Glove
  5. carmeli, 2010, Hand Tutor Enhanced Hand Rehabilitation after Stroke A Pilot Study
  6. 10.1016/j.apmr.2005.08.127 · DOI
  7. 10.1016/0022-510X(95)00003-K · DOI · Paper page
  8. 10.1191/0269215504cr715oa · DOI · Paper page
  9. jugenheimer, 2001, A robot for hand rehabillitation, Massachusetts Institute of Technology
  10. 10.1108/01439910910980141 · DOI · Paper page
  11. 2008, Dean Kamen's Luke Arm Prosthesis Readis for Clinical Trials
  12. 10.1016/j.rehab.2008.10.003 · DOI · Paper page
  13. 10.1016/S1569-1861(09)70031-2 · DOI
  14. 10.1186/1743-0003-8-50 · DOI
  15. 10.1109/TMECH.2010.2090353 · doi:10.1109/tmech.2010.2090353

Cited by

Metadata

Authors
Delph, M. A., Fischer, S. A., Gauthier, P. W., Luna, C. H. M., Clancy, E. A., & Fischer, G. S.
Venue
2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR)
Publisher
IEEE
Published
2013-06
Volume
2013
Pages
1-7
ISSN
1945-7898 (ISSN-L)
OpenAlex
W1965019276
Cited by
119
References
0
FWCI
5.94
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.