Cited by 3Non-Invasive Vital Sign MonitoringContext-Aware Activity Recognition SystemsHealthcare Technology and Patient Monitoring

Human State Classification and Predication for Critical Care Monitoring by Real-Time Bio-signal Analysis

Li, Xiaokun, Porikli, Fatih·2010·2010 20th International Conference on Pattern Recognition

Abstract

To address the challenges in critical care monitoring, we present a multi-modality bio-signal modeling and analysis modeling framework for real-time human state classification and predication. The novel bioinformatic framework is developed to solve the human state classification and predication issues from two aspects: a) achieve 1:1 mapping between the bio-signal and the human state via discriminant feature analysis and selection by using probabilistic principle component analysis (PPCA); b) avoid time-consuming data analysis and extensive integration resources by using Dynamic Bayesian Network (DBN). In addition, intelligent and automatic selection of the most suitable sensors from the bio-sensor array is also integrated in the proposed DBN.

Integrity signals

Registry

Crossref · 10.1109/icpr.2010.602

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Li, X., & Porikli, F.
Affiliations
  • Northrop Grumman (United States) (US)
  • Mitsubishi Electric Research Laboratories (United States) (US)
Venue
2010 20th International Conference on Pattern Recognition
Publisher
IEEE
Published
2010-08
Volume
34
Pages
2460-2463
ISSN
1041-3278 (ISSN-L)
OpenAlex
W2069257788
Cited by
3
References
5
Citations by year
2021: 1 · 2017: 1 · 2013: 1
FWCI
0.74
Type
conference paper
Language
en
Open access
closed
Locations
  • Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition (publishedVersion)
  • ANU Open Research (Australian National University) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
intensive care monitoring, probabilistic principal component analysis, dynamic Bayesian networks, sensor selection, biosensor arrays

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review