The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
An open-source research kit for the da Vinci® Surgical System
Abstract
We present a telerobotics research platform that provides complete access to all levels of control via open-source electronics and software. The electronics employs an FPGA to enable a centralized computation and distributed I/O architecture in which all control computations are implemented in a familiar development environment (Linux PC) and low-latency I/O is performed over an IEEE-1394a (FireWire) bus at speeds up to 400 Mbits/sec. The mechanical components are obtained from retired first-generation da Vinci ® Surgical Systems. This system is currently installed at 11 research institutions, with additional installations underway, thereby creating a research community around a common open-source hardware and software platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ROS: an open-source Robot Operating System
Quigley, M. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · Cited by 8,729
Raven-II: An Open Platform for Surgical Robotics Research
Hannaford, B., Rosen, J., Friedman, D. W., King, H., Roan, P., Cheng, L., Glozman, D., Ma, J., Kosari, S. N., & White, L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2228858 · Cited by 372
The real-time motion control core of the Orocos project
Bruyninckx, H., Soetens, P., & Koninckx, B. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1242011 · Cited by 199
The DLR MIRO: a versatile lightweight robot for surgical applications
Hagn, U., Nickl, M., Jörg, S., Passig, G., Bahls, T., Nothhelfer, A., Hacker, F., Le‐Tien, L., Albu‐Schäffer, A., Konietschke, R., et al. (2008) · Industrial Robot: An International Journal · doi:10.1108/01439910810876427 · Cited by 188
Late motor processing in low-impedance robots: impedance control of series-elastic actuators
Pratt, G. A., Willisson, P., Bolton, C., & Hofman, A. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1384410 · Cited by 128
Real-time perception-guided motion planning for a personal robot
Rusu, R. B., Sucan, I. A., Gerkey, B. P., Chitta, S., Beetz, M., & Kavraki, L. E. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354396 · Cited by 81
Software components and frameworks for medical robot control
Kapoor, A., Deguet, A., & Kazanzides, P. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642285 · Cited by 48
Self-citationThe da Vinci Research Interface
DiMaio, S., & Hasser, C. J. (2008) · doi:10.54294/om9m8e · Cited by 35
Self-citationThe Surgical Assistant Workstation (SAW) in Minimally-Invasive Surgery and Microsurgery
Kazanzides, P., DiMaio, S., Deguet, A., Vágvölgyi, B., Balicki, M. A., Schneider, C., Kumar, R., Jog, A., Itkowitz, B., Hasser, C. J., et al. (2010) · doi:10.54294/pr2z99 · Cited by 19
Self-citation
Cited by
Aceto, G., Persico, V., & Pescapé, A. (2018) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2018.02.008 · Cited by 504
Adverse Events in Robotic Surgery: A Retrospective Study of 14 Years of FDA Data
Alemzadeh, H., Raman, J., Leveson, N., Kalbarczyk, Z., & Iyer, R. K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151470 · Cited by 441
Qi, W., Ovur, S. E., Li, Z., Marzullo, A., & Song, R. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3089999 · Cited by 253
Thananjeyan, B., Garg, A., Krishnan, S., Chen, C., Miller, L., & Goldberg, K. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989275 · Cited by 144
ToolNet: Holistically-nested real-time segmentation of robotic surgical tools
Garcia-Peraza-Herrera, L. C., Li, W., Fidon, L., Gruijthuijsen, C., Devreker, A., Attilakos, G., Deprest, J., Poorten, E. V., Stoyanov, D., Vercauteren, T., et al. (2017) · 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8206462 · Cited by 137
Metadata
- Authors
- Kazanzides, P., Chen, Z., Deguet, A., Fischer, G. S., Taylor, R. H., & DiMaio, S. P.
- Venue
- 2014 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2014-05
- Pages
- 6434-6439
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2061417916
- Cited by
- 493
- References
- 9
- FWCI
- 50.34
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An open-source research kit for the da Vinci® Surgical System. https://app.cochat.ai/papers/10.1109/icra.2014.6907809
- The paper
- Kazanzides, P., Chen, Z., Deguet, A., Fischer, G. S., Taylor, R. H., & DiMaio, S. P. (2014). An open-source research kit for the da Vinci® Surgical System. 2014 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2014.6907809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.