The DOI matches its Crossref record.
Development of a polymer-based tendon-driven wearable robotic hand
Abstract
This paper presents the development of a polymer-based tendon-driven wearable robotic hand, Exo-Glove Poly. Unlike the previously developed Exo-Glove, a fabric-based tendon-driven wearable robotic hand, Exo-Glove Poly was developed using silicone to allow for sanitization between users in multiple-user environments such as hospitals. Exo-Glove Poly was developed to use two motors, one for the thumb and the other for the index/middle finger, and an under-actuation mechanism to grasp various objects. In order to realize Exo-Glove Poly, design features and fabrication processes were developed to permit adjustment to different hand sizes, to protect users from injury, to enable ventilation, and to embed Teflon tubes for the wire paths. The mechanical properties of Exo-Glove Poly were verified with a healthy subject through a wrap grasp experiment using a mat-type pressure sensor and an under-actuation performance experiment with a specialized test set-up. Finally, performance of the Exo-Glove Poly for grasping various shapes of object was verified, including objects needing under-actuation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320
Yap, H. K., Khin, P. M., Koh, T. H., Sun, Y., Liang, X., Lim, J. H., & Yeow, C.-H. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2669366 · Cited by 277
Soft Sensors and Actuators for Wearable Human–Machine Interfaces
Park, J., Lee, Y., Cho, S., Choe, A., Yeom, J., Ro, Y. G., Kim, J., Kang, D.-H., Lee, S., & Ko, H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00356 · Cited by 272
Human-in-the-loop development of soft wearable robots
Walsh, C. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0011-1 · Cited by 176
Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
Metadata
- Authors
- Kang, B. B., Lee, H., In, H., Jeong, U., Chung, J., & Cho, K.-J.
- Venue
- 2016 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 3750-3755
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2414587816
- Cited by
- 164
- References
- 0
- FWCI
- 43.89
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a polymer-based tendon-driven wearable robotic hand. https://app.cochat.ai/papers/10.1109/icra.2016.7487562
- The paper
- Kang, B. B., Lee, H., In, H., Jeong, U., Chung, J., & Cho, K.-J. (2016). Development of a polymer-based tendon-driven wearable robotic hand. 2016 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2016.7487562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.