Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications

Abstract

Stroke has become the leading cause of disability and the second-leading cause of mortality worldwide. Dyskinesia complications are the major reason of these high death and disability rates. As a tool for rapid motion function recovery in stroke patients, exoskeleton robots can reduce complications and thereby decrease stroke mortality rates. However, existing exoskeleton robots interfere with the wearer's natural motion and damage joints and muscles due to poor human-machine coupling. In this paper, a novel ergonomic soft bionic exoskeleton robot with 7 degrees of freedom was proposed to address these problems based on the principles of functional anatomy and sports biomechanics. First, the human motion system was analysed according to the functional anatomy, and the muscles were modelled as tension lines. Second, a soft bionic robot was established based on the musculoskeletal tension line model. Third, a robot control method mimicking human muscle control principles was proposed and optimized on a humanoid platform manufactured using 3D printing. After the control method was optimized, the motion trajectory similarities between humans and the platform exceeded 87%. Fourth, the force-assisted effect was tested based on electromyogram signals, and the results showed that muscle signals decreased by 58.17% after robot assistance. Finally, motion-assistance experiments were performed with stroke patients. The joint movement level increased by 174% with assistance, which allowed patients to engage in activities of daily living. With this robot, stroke patients could recover their motion functions, preventing complications and decreasing fatality and disability rates.

Overview

Integrity signals

Registry

Crossref · 10.1088/1748-3190/aad8d4

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 50 references

Research works printed but not linked: 2

  1. Park Y L, 2014, Bioinspir. Biomim., 9
  2. Chen J Z, 2010, Smart Mater. Struct., 19

Cited by

See all 92

Metadata

Authors
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L.
Affiliations
  • Shenyang Institute of Automation (CN)
  • American University of Beirut (LB)
Venue
Bioinspiration & Biomimetics
Published
2018-08-24
Volume
13
Issue
6
Pages
066001
ISSN
  • 1748-3182 (ISSN-L)
  • 1748-3190
OpenAlex
W2885878610
Cited by
92
References
50
Citations by year
2026: 9 · 2025: 7 · 2024: 11 · 2023: 23 · 2022: 18 · 2021: 11 · 2020: 8 · 2019: 5
FWCI
2.40
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Bioinspiration & Biomimetics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (61433017, 61573341)
  • National Key Research and Development Program of China (2016YFE0206200)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
soft exoskeleton, upper limb rehabilitation, stroke, dyskinesia, bionic robot, functional anatomy, sports biomechanics, electromyography control, muscle fatigue reduction, 3D printing, human-machine coupling, stroke recovery
MeSH terms
Exoskeleton Device, Activities of Daily Living, Animals, Biomechanical Phenomena, Electromyography, Humans, Movement, Robotics, Range of Motion, Articular, Muscle, Skeletal, Stroke, Upper Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications. https://app.cochat.ai/papers/10.1088/1748-3190/aad8d4
The paper
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018). Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications. Bioinspiration & Biomimetics. https://doi.org/10.1088/1748-3190/aad8d4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.