Curvature control of soft orthotics via low cost solid-state optics
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A soft orthotic with position control enabled via embedded optical fiber is presented. The design, manufacture, and integration of both the pneumatically powered actuators and optical sensors are described. This orthotic actuator-sensor pair is self-contained and worn on a human finger. When un-powered, the elastomeric actuator allows facile movement and, when pneumatically actuated, the orthotic causes bending of the wearer's finger. Position control is achieved by measurement of signal intensity from a light-emitting diode (LED) input traveling through an embedded optical fiber—greater curvature results in increased light intensity. Both the static and dynamic states are monitored via the optical sensor and the prescribed curvatures are achieved accurately and with stability by a gain-scheduled proportional-integral-derivative (PID) controller implemented by applying pulse-width-modulation (PWM) signals to a solenoid valve to adjust the internal pressure of the actuator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Recipe for Soft Fluidic Elastomer Robots
Marchese, A. D., Katzschmann, R. K., & Rus, D. (2015) · Soft Robotics · doi:10.1089/soro.2014.0022 · Cited by 649
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335 · cited 1×
“Though intrinsically compliant actuators like McKibben Artificial Muscles [3] [4] have existed for decades, new designs of fluidically-powered elastomeric actuator (FEAs) [5] [6] have shown great potential as wearable orthotics.”
Background
Cited by
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Self-citationTriboelectric nanogenerator sensors for soft robotics aiming at digital twin applications
Jin, T., Sun, Z., Li, L., Zhang, Q., Zhu, M., Zhang, Z., Yuan, G., Chen, T., Tian, Y., Hou, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19059-3 · Cited by 695
Sun, Z., Zhu, M., Zhang, Z., Chen, Z., Shi, Q., Shan, X., Yeow, R. C. H., & Lee, C. (2021) · Advanced Science · doi:10.1002/advs.202100230 · Cited by 270
Soft optoelectronic sensory foams with proprioception
Van Meerbeek, I. M., De Sa, C. M., & Shepherd, R. F. (2018) · Science Robotics · doi:10.1126/scirobotics.aau2489 · Cited by 203
Self-citationA Helping Hand: Soft Orthosis with Integrated Optical Strain Sensors and EMG Control
Zhao, H., Jalving, J., Huang, R., Knepper, R., Ruina, A., & Shepherd, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582216 · Cited by 191
“Force Test with the EMG Signal We did a force test for each finger actuator [19] and the output tip force ranged from 0 to 5 N, by applying pressure ranging from 0 to 270 kPa [24].”
Self-citation
Metadata
- Authors
- Zhao, H., Huang, R., & Shepherd, R. F.
- Venue
- 2016 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 4008-4013
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2412969968
- Cited by
- 53
- References
- 2
- FWCI
- 16.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Curvature control of soft orthotics via low cost solid-state optics. https://app.cochat.ai/papers/10.1109/icra.2016.7487590
- The paper
- Zhao, H., Huang, R., & Shepherd, R. F. (2016). Curvature control of soft orthotics via low cost solid-state optics. 2016 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2016.7487590
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.