Automating multi-throw multilateral surgical suturing with a mechanical needle guide and sequential convex optimization
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
For supervised automation of multi-throw suturing in Robot-Assisted Minimally Invasive Surgery, we present a novel mechanical needle guide and a framework for optimizing needle size, trajectory, and control parameters using sequential convex programming. The Suture Needle Angular Positioner (SNAP) results in a 3x error reduction in the needle pose estimate in comparison with the standard actuator. We evaluate the algorithm and SNAP on a da Vinci Research Kit using tissue phantoms and compare completion time with that of humans from the JIGSAWS dataset [5]. Initial results suggest that the dVRK can perform suturing at 30% of human speed while completing 86% suture throws attempted. Videos and data are available at: berkeleyautomation.github.io/amts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point Set Registration: Coherent Point Drift
Myronenko, A., & Song, X. (2010) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.46 · Cited by 2,762 · cited 1×
“In practice, needles vary in length in increments of 1 mm and vary in three different fractions of a circle.”
Laparoscopic surgery versus open surgery for colon cancer: short-term outcomes of a randomised trial
(2005) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70221-7 · Cited by 2,316
Motion planning with sequential convex optimization and convex collision checking
Schulman, J., Duan, Y., Ho, J., Lee, A., Awwal, I., Bradlow, H., Pan, J., Patil, S., Goldberg, K., & Abbeel, P. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914528132 · Cited by 866 · cited 1×
“…paper The authors are with University of California, Berkeley, CA USA 94720 1EECS, {siddarthsen, yjen}@berkeley.edu 2IEOR & EECS, {animesh.garg, goldberg}@berkeley.edu 3Mechanical Engineering, {dgealy, mckinley}@berkeley.edu complete 86% of attempted throws at 30% the speed of human operators [5].”
Self-citationAn open-source research kit for the da Vinci® Surgical System
Kazanzides, P., Chen, Z., Deguet, A., Fischer, G. S., Taylor, R. H., & DiMaio, S. P. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907809 · Cited by 493 · cited 1×
“Hopkins University [12].”
Finding Locally Optimal, Collision-Free Trajectories with Sequential Convex Optimization
Schulman, J., Ho, J., Lee, A., Awwal, I., Bradlow, H., & Abbeel, P. (2013) · Robotics: Science and Systems IX · doi:10.15607/rss.2013.ix.031 · Cited by 430 · cited 1×
“RSAs are being used for many tumorectomy interventions within the abdominal and thoracic cavities such as prostectomy and hysterectomy [2, 25] as described in reviews of recent developments in semi-autonomous and autonomous execution of surgical procedures by Moustris et al. [20] and Kranzfelder et…”
Evolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321 · cited 1×
“…paper The authors are with University of California, Berkeley, CA USA 94720 1EECS, {siddarthsen, yjen}@berkeley.edu 2IEOR & EECS, {animesh.garg, goldberg}@berkeley.edu 3Mechanical Engineering, {dgealy, mckinley}@berkeley.edu complete 86% of attempted throws at 30% the speed of human operators [5].”
van den Berg, J., Miller, S., Duckworth, D., Hu, H., Wan, A., Fu, X.-Y., Goldberg, K., & Abbeel, P. (2010) · 2010 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2010.5509621 · Cited by 233 · cited 1×
“human speeds [36].”
Self-citationSuture Choice and Other Methods of Skin Closure
Hochberg, J., Meyer, K. M., & Marion, M. D. (2009) · Surgical Clinics of North America · doi:10.1016/j.suc.2009.03.001 · Cited by 195 · cited 1×
“A curved needle with suture thread is repeatedly pushed through a pair of tissue boundaries with one actuator, then pulled through with a second actuator until the thread is taut, then is transferred back to the first actuator to begin the next throw / suture [1, 6].”
Learning grounded finite-state representations from unstructured demonstrations
Niekum, S., Osentoski, S., Konidaris, G., Chitta, S., Marthi, B., & Barto, A. G. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914554471 · Cited by 187 · cited 1×
“…paper The authors are with University of California, Berkeley, CA USA 94720 1EECS, {siddarthsen, yjen}@berkeley.edu 2IEOR & EECS, {animesh.garg, goldberg}@berkeley.edu 3Mechanical Engineering, {dgealy, mckinley}@berkeley.edu complete 86% of attempted throws at 30% the speed of human operators [5].”
Burch, J. M., Franciose, R. J., Moore, E. E., Biffl, W. L., & Offner, P. J. (2000) · Annals of Surgery · doi:10.1097/00000658-200006000-00007 · Cited by 184 · cited 1×
“actuator to begin the next throw / suture [1, 6].”
Cited by
Attanasio, A., Scaglioni, B., De Momi, E., Fiorini, P., & Valdastri, P. (2021) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-062420-090543 · Cited by 263
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Self-citationThananjeyan, B., Garg, A., Krishnan, S., Chen, C., Miller, L., & Goldberg, K. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989275 · Cited by 144
“We use the Intuitive Surgical da Vinci Research Kit (dVRK) surgical robot assistant, as in [13, 21, 28].”
MethodSelf-citationAutonomy in surgical robots and its meaningful human control
Ficuciello, F., Tamburrini, G., Arezzo, A., Villani, L., & Siciliano, B. (2019) · Paladyn, Journal of Behavioral Robotics · doi:10.1515/pjbr-2019-0002 · Cited by 92
Metadata
- Authors
- Sen, S., Garg, A., Gealy, D. V., McKinley, S., Jen, Y., & Goldberg, K.
- Venue
- 2016 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 4178-4185
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2341108136
- Cited by
- 159
- References
- 26
- FWCI
- 33.25
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automating multi-throw multilateral surgical suturing with a mechanical needle guide and sequential convex optimization. https://app.cochat.ai/papers/10.1109/icra.2016.7487611
- The paper
- Sen, S., Garg, A., Gealy, D. V., McKinley, S., Jen, Y., & Goldberg, K. (2016). Automating multi-throw multilateral surgical suturing with a mechanical needle guide and sequential convex optimization. 2016 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2016.7487611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.