The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fully autonomous hip exoskeleton saves metabolic cost of walking
Abstract
We have developed a hip exoskeleton for seniors with difficulties in walking due to muscle weakness. The exoskeleton is lightweight and moderate in assistance power compared to other hip exoskeletons in the literature. Its controller estimates user gait phase, walking speed, and ground inclinations to generate assistance torque adaptively. To assess the physiological effect of the gait assistance, we compared metabolic energy consumption for 5 adults for walking on a treadmill with and without the exoskeleton at the same speed: the exoskeleton reduced metabolic cost of walking by 13% (p = 0:0024). The step length and the stride time increased under the assistance. Our analysis for the result suggests that the efficiency of hip exoskeletons on saving metabolic energy can be twice as high as that of ankle exoskeletons possibly because muscle-tendon unit in the hip joint is less energy-efficient than in the ankle joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mechanics of active fin-shape control in ray-finned fishes
Alben, S., Madden, P. G., & Lauder, G. V. (2007) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0181 · Cited by 160
Cited by
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Personalizing exoskeleton assistance while walking in the real world
Slade, P., Kochenderfer, M. J., Delp, S. L., & Collins, S. H. (2022) · Nature · doi:10.1038/s41586-022-05191-1 · Cited by 328
Metadata
- Authors
- Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y.
- Venue
- 2016 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2016-05
- Pages
- 4628-4635
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2411309527
- Cited by
- 177
- References
- 1
- FWCI
- 31.92
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.