Fast and Reliable Autonomous Surgical Debridement with Cable-Driven Robots Using a Two-Phase Calibration Procedure
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Automating precision subtasks such as debridement (removing dead or diseased tissue fragments) with Robotic Surgical Assistants (RSAs) such as the da Vinci Research Kit (dVRK) is challenging due to inherent nOnlinearities in cable-driven systems. We propose and evaluate a novel two-phase coarse-to-fine calibration method. In Phase I (coarse), we place a red calibration marker on the end effector and let it randomly move through a set of open-loop trajectories to obtain a large sample set of camera pixels and internal robot end-effector configurations. This coarse data is then used to train a Deep Neural Network (DNN) to learn the coarse transformation bias. In Phase II (fine), the bias from Phase I is applied to move the end -effector toward a small set of specific target points on a printed sheet. For each target, a human operator manually adjusts the end -effector position by direct contact (not through teleoperation) and the residual compensation bias is recorded. This fine data is then used to train a Random Forest (RF) to learn the fine transformation bias. Subsequent experiments suggest that without calibration, position errors average 4.55mm. Phase I can reduce average error to 2.14mm and the combination of Phase I and Phase II can reduces average error to 1.08mm. We apply these results to debridement of raisins and pumpkin seeds as fragment phantoms. Using an endoscopic stereo camera with standard edge detection, experiments with 120 trials achieved average success rates of 94.5 %, exceeding prior results with much larger fragments (89.4%) and achieving a speedup of 2.1x, decreasing time per fragment from 15.8 seconds to 7.3 seconds. Source code, data, and videos are available at https://sites.google.com/view/calib-icra/.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Levine, S., Pastor, P., Krizhevsky, A., Ibarz, J., & Quillen, D. (2018) · The International Journal of Robotics Research · doi:10.1177/0278364917710318 · Cited by 1,971
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Kassahun, Y., Yu, B., Tibebu, A. T., Stoyanov, D., Giannarou, S., Metzen, J. H., & Vander Poorten, E. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1305-z · Cited by 238
Thananjeyan, B., Garg, A., Krishnan, S., Chen, C., Miller, L., & Goldberg, K. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989275 · Cited by 144
Self-citation
Cited by
Deep Learning Applications in Medical Image Analysis
Ker, J., Wang, L., Rao, J., & Lim, T. (2018) · IEEE Access · doi:10.1109/access.2017.2788044 · Cited by 1,481
Open-Sourced Reinforcement Learning Environments for Surgical Robotics
Richter, F., Orosco, R. K., & Yip, M. C. (2019) · arXiv · doi:10.48550/arxiv.1903.02090 · Cited by 92
Thananjeyan, B., Balakrishna, A., Rosolia, U., Li, F., McAllister, R., Gonzalez, J. E., Levine, S., Borrelli, F., & Goldberg, K. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2976272 · Cited by 83
Self-citationVisuoSpatial Foresight for Multi-Step, Multi-Task Fabric Manipulation
Hoque, R., Seita, D., Balakrishna, A., Ganapathi, A., Tanwani, A., Jamali, N., Yamane, K., Iba, S., & Goldberg, K. (2020) · Robotics: Science and Systems XVI · doi:10.15607/rss.2020.xvi.034 · Cited by 74
Self-citationVisuospatial foresight for physical sequential fabric manipulation
Hoque, R., Seita, D., Balakrishna, A., Ganapathi, A., Tanwani, A. K., Jamali, N., Yamane, K., Iba, S., & Goldberg, K. (2022) · Autonomous Robots · doi:10.1007/s10514-021-10001-0 · Cited by 45
Self-citation
Metadata
- Authors
- Seita, D., Krishnan, S., Fox, R., McKinley, S., Canny, J., & Goldberg, K.
- Venue
- 2018 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2018-05
- Pages
- 6651-6658
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2963553847
- Cited by
- 67
- References
- 5
- FWCI
- 23.70
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast and Reliable Autonomous Surgical Debridement with Cable-Driven Robots Using a Two-Phase Calibration Procedure. https://app.cochat.ai/papers/10.1109/icra.2018.8460583
- The paper
- Seita, D., Krishnan, S., Fox, R., McKinley, S., Canny, J., & Goldberg, K. (2018). Fast and Reliable Autonomous Surgical Debridement with Cable-Driven Robots Using a Two-Phase Calibration Procedure. 2018 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2018.8460583
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.