A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Hemiparetic gait after stroke is typically asymmetric and energetically inefficient. A major contributor to walking deficits is impaired paretic ankle function. Impaired paretic ankle plantarflexion (PF) reduces forward propulsion symmetry and impaired paretic ankle dorsiflexion (DF) diminishes ground clearance during swing. We have developed soft wearable robots (soft exosuits) to assist paretic PF and DF during walking after stroke. Through experimental studies with poststroke patients, we have demonstrated that exosuits can improve forward propulsion symmetry and ground clearance in walking, ultimately reducing the metabolic cost of walking. This paper presents an optimized soft exosuit aimed at use in clinical gait training for patients poststroke. The optimized exosuit is lightweight, easy to don and doff, and capable of efficiently delivering mechanical assistance to the paretic ankle. This paper focuses on the optimized controller that can deliver well-timed consistent ankle assistance to patients. A preliminary study was performed using this exosuit with three poststroke patients with heterogeneous gait patterns. Results showed that compared to a previously published controller, more consistent assistive force profiles could be delivered to individuals poststroke while consuming 50% less electrical power. Additionally, a preliminary biomechanical assessment was performed during overground walking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationA biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450 · cited 1×
“a nonlinear spring with hysteresis that presents different mechanical behaviors in loading and unloading [12], [23].”
BackgroundSelf-citation
Cited by
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Porciuncula, F., Roto, A. V., Kumar, D., Davis, I., Roy, S., Walsh, C. J., & Awad, L. N. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.013 · Cited by 300
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Self-citationGrimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Self-citation
Metadata
- Authors
- Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., Kudzia, P., Ellis, T., Awad, L., & Walsh, C. J.
- Venue
- 2018 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2018-05
- Pages
- 2820-2827
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2890784218
- Cited by
- 145
- References
- 2
- FWCI
- 32.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.