The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
A biologically inspired soft exosuit for walking assistance
Abstract
We present the design and evaluation of a multi-articular soft exosuit that is portable, fully autonomous, and provides assistive torques to the wearer at the ankle and hip during walking. Traditional rigid exoskeletons can be challenging to perfectly align with a wearer’s biological joints and can have large inertias, which can lead to the wearer altering their natural motion patterns. Exosuits, in comparison, use textiles to create tensile forces over the body in parallel with the muscles, enabling them to be light and not restrict the wearer’s kinematics. We describe the biologically inspired design and function of our exosuit, including a simplified model of the suit’s architecture and its interaction with the body. A key feature of the exosuit is that it can generate forces passively due to the body’s motion, similar to the body’s ligaments and tendons. These passively generated forces can be supplemented by actively contracting Bowden cables using geared electric motors, to create peak forces in the suit of up to 200 N. We define the suit–human series stiffness as an important parameter in the design of the exosuit and measure it on several subjects, and we perform human subjects testing to determine the biomechanical and physiological effects of the suit. Results from a five-subject study showed a minimal effect on gait kinematics and an average best-case metabolic reduction of 6.4%, comparing suit worn unpowered versus powered, during loaded walking with 34.6 kg of carried mass including the exosuit and actuators (2.0 kg on both legs, 10.1 kg total).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Soft-robotic systems therefore show great potential in medical and wearable applications.[462–464]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [462]
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359 · cited 2×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundEfficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873 · cited 1×
“Finally, both humans and passive dynamic walkers use small amounts of input energy at specific times in the gait cycle during walking (McGeer, 1990; Collins et al., 2005).”
BackgroundLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“Other systems were designed to augment healthy individuals, but these could also be used with impaired individuals for rehabilitation or assistance purposes, perhaps with modifications to their control strategies (Dollar and Herr, 2008; Herr, 2009).”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundGait Analysis: Normal and Pathological Function
Grant, A. D. (2010) · JAMA · doi:10.1001/jama.2010.1210 · Cited by 1,123
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Devices in the former category are intended to be used by paralyzed individuals, enabling them to walk when they were previously unable to do so (Ackerman, 2010; Neuhaus et al., 2011; Esquenazi et al., 2012).”
BackgroundDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603 · cited 2×
“The distribution of the mass is important as prior biomechanics studies have identified that mass at the foot during walking has a metabolic cost of 7.5% to 8.5% per kg of total added mass, as compared to 1% to 2% for mass at the waist (Rose and Gamble, 2006; Browning et al., 2007).”
BackgroundInfluentialDerivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Research works printed but not linked: 7
- Brockway JM, 1987, Human Nutrition. Clinical Nutrition, 41, 463
- In H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Neuhaus PD, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Quintero H, 2011, 2011 IEEE international conference on rehabilitation robotics (ICORR), 1
- Rose J, 2006, Human Walking
- 10.1155/2009/829219 · doi:10.1155/2009/829219
- Vanoglio F, 2013, XIII congress of Italian Society of Neurorehabilitation
Cited by
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing
Frutiger, A., Muth, J. T., Vogt, D. M., Mengüç, Y., Campo, A., Valentine, A. D., Walsh, C. J., & Lewis, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201500072 · Cited by 468
Self-citationSystematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Metadata
- Authors
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J.
- Affiliations
- Harvard University (US)
- Harvard University, Cambridge, MA, USA
- Boston University (US)
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2015-03-16
- Volume
- 34
- Issue
- 6
- Pages
- 744-762
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2169410184
- Semantic Scholar
- 6f5747b1e1a55a0b7c475d4d70e90e139f3e74d5
- Cited by
- 450
- References
- 66
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 38 · 2023: 40 · 2022: 39 · 2021: 63 · 2020: 48 · 2019: 43 · 2018: 42 · 2017: 33 · 2016: 21 · 2015: 4
- FWCI
- 16.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, gait assistance, biologically inspired design, energy cost of walking, loaded walking, gait kinematics, wearable robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A biologically inspired soft exosuit for walking assistance. https://app.cochat.ai/papers/10.1177/0278364914562476
- The paper
- Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015). A biologically inspired soft exosuit for walking assistance. The International Journal of Robotics Research. https://doi.org/10.1177/0278364914562476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.