The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Power assist method for HAL-3 using EMG-based feedback controller
Abstract
We have developed the exoskeletal robotics suite HAL (Hybrid Assistive Leg) which is integrated with human and assists suitable power for lower limb of people with gait disorder. This study proposes the method of assist motion and assist torque to realize a power assist corresponding to the operator's intention. In the method of assist motion, we adopted Phase Sequence control which generates a series of assist motions by transiting some simple basic motions called Phase. We used the feedback controller to adjust the assist torque to maintain myoelectricity signals which were generated while performing the power assist walking. The experiment results showed the effective power assist according to operator's intention by using these control, methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Legged Locomotion Robots and Anthropomorphic Mechanisms
Stephanou, H. E., & Saridis, G. N. (1976) · Computers & Mathematics with Applications · doi:10.1016/0898-1221(76)90030-4 · Cited by 86
Exoskeletons for Human Performance Augmentation (EHPA): A Program Summary.
Garcia, E., Sater, J. M., & Main, J. A. (2002) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.20.822 · Cited by 64
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Surface EMG has been demonstrated for this purpose in transfemoral prostheses [61,120,130,132,149,150], virtual above- and below-knee prostheses [151], a hip and knee orthosis [152], knee orthoses [60,153,154], a transtibial prosthesis [66] and an ankle-foot orthosis [155].”
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Biorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Metadata
- Authors
- Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y.
- Venue
- SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483)
- Publisher
- IEEE
- Published
- 2004-04-23
- Volume
- 2
- Pages
- 1648-1653
- ISSN
- 1062-922X (ISSN-L)
- OpenAlex
- W2154128597
- Cited by
- 392
- References
- 3
- FWCI
- 13.08
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.