Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 232 of the 234 references it cites were found in a registry or an index, and 2 are not checked yet.

Control strategies for active lower extremity prosthetics and orthotics: a review

Open access
Tucker, Michael R, Olivier, Jeremy, Pagel, Anna, Bleuler, Hannes, Bouri, Mohamed, Lambercy, Olivier, Millán, José del R, Riener, Robert, Vallery, Heike, Gassert, Roger · 2015 · Journal of NeuroEngineering and Rehabilitation

Abstract

: Technological advancements have led to the development of numerous wearable robotic devices for the physical assistance and restoration of human locomotion. While many challenges remain with respect to the mechanical design of such devices, it is at least equally challenging and important to develop strategies to control them in concert with the intentions of the user.This work reviews the state-of-the-art techniques for controlling portable active lower limb prosthetic and orthotic (P/O) devices in the context of locomotive activities of daily living (ADL), and considers how these can be interfaced with the user's sensory-motor control system. This review underscores the practical challenges and opportunities associated with P/O control, which can be used to accelerate future developments in this field. Furthermore, this work provides a classification scheme for the comparison of the various control strategies.As a novel contribution, a general framework for the control of portable gait-assistance devices is proposed. This framework accounts for the physical and informatic interactions between the controller, the user, the environment, and the mechanical device itself. Such a treatment of P/Os--not as independent devices, but as actors within an ecosystem--is suggested to be necessary to structure the next generation of intelligent and multifunctional controllers.Each element of the proposed framework is discussed with respect to the role that it plays in the assistance of locomotion, along with how its states can be sensed as inputs to the controller. The reviewed controllers are shown to fit within different levels of a hierarchical scheme, which loosely resembles the structure and functionality of the nominal human central nervous system (CNS). Active and passive safety mechanisms are considered to be central aspects underlying all of P/O design and control, and are shown to be critical for regulatory approval of such devices for real-world use.The works discussed herein provide evidence that, while we are getting ever closer, significant challenges still exist for the development of controllers for portable powered P/O devices that can seamlessly integrate with the user's neuromusculoskeletal system and are practical for use in locomotive ADL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-0003-12-1

Cites

232 of 234 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Generalized control framework for active lower limb prostheses and orthoses. The proposed framework illustrates the physical and signal-level interactions between a powered lower limb prosthetic or orthotic (P/O) device, a user, and his environment. The arrows indicate the exchange of power and information between the various components of the P/O ecosystem. A hierarchical control structure is implemented, with the estimation of the user’s locomotive intent taking place at the high level, translation of the user’s intent to a desired device state at the mid level, and a device-specific controller responsible for realizing the desired device state at the low level. Safety mechanisms underly all aspects of P/O design, including those which are mechanically passive and those which are actively controlled. Adapted from Varol et al. 2010 [24].
Figure 1 Generalized control framework for active lower limb prostheses and orthoses. The proposed framework illustrates the physical and signal-level interactions between a powered lower limb prosthetic or orthotic (P/O) device, a user, and his environment. The arrows indicate the exchange of power and information between the various components of the P/O ecosystem. A hierarchical control structure is implemented, with the estimation of the user’s locomotive intent taking place at the high level, translation of the user’s intent to a desired device state at the mid level, and a device-specific controller responsible for realizing the desired device state at the low level. Safety mechanisms underly all aspects of P/O design, including those which are mechanically passive and those which are actively controlled. Adapted from Varol et al. 2010 [24].CC BY · PubMed Central
Figure 2 Nominal sensory-motor control loop for human locomotion. Motion intentions originate from supraspinal input, which along with afferent feedback serves to modulate basic underlying locomotor patterns within a network of spinal interneurons, commonly referred to as the central pattern generator (CPG). Efferent stimulation is transmitted through motor neurons to individual muscle groups, which are recruited to effect the movement. Afferent feedback, including that from proprioceptors of the muscles and joints and mechanoreceptors of the skin, is used to directly modulate motor commands via mono- and polysynaptic reflex arcs, thus contributing to the efficiency of gait under normal conditions and stability of gait in the face of unexpected perturbations. Sensory information is also transmitted to the brain, where it is combined with higher level inputs from the visual, auditory, and vestibular systems to provide information required for the maintenance of balance, orientation and control of precise movements.
Figure 2 Nominal sensory-motor control loop for human locomotion. Motion intentions originate from supraspinal input, which along with afferent feedback serves to modulate basic underlying locomotor patterns within a network of spinal interneurons, commonly referred to as the central pattern generator (CPG). Efferent stimulation is transmitted through motor neurons to individual muscle groups, which are recruited to effect the movement. Afferent feedback, including that from proprioceptors of the muscles and joints and mechanoreceptors of the skin, is used to directly modulate motor commands via mono- and polysynaptic reflex arcs, thus contributing to the efficiency of gait under normal conditions and stability of gait in the face of unexpected perturbations. Sensory information is also transmitted to the brain, where it is combined with higher level inputs from the visual, auditory, and vestibular systems to provide information required for the maintenance of balance, orientation and control of precise movements.CC BY · PubMed Central
Figure 3 Finite-state decompostition of level human gait. Steady-state locomotion can be represented as a periodic sequence of states (or phases), where the transitions between the states are triggered by events within the gait cycle. The choice of the number of states and the type of events used are somewhat arbitrary, and will depend on what information is available from the sensors and which joint the P/O is to actuate. In this example for the knee joints, stance has been divided into three states, with early and middle stance initiated by ground contact events at the heel and toe of the foot, for example determined using pressure sensitive insoles. Late stance is triggered when the user’s center of mass is estimated to be over the ankle, again using the insoles or estimates of the user’s whole-body posture through joint position sensing or inertial measurements. Swing flexion begins as the toe of the foot leaves the ground, and swing extension begins as the knee’s velocity is sensed to be less than zero. The cycle begins again as the heel comes into contact with the ground.
Figure 3 Finite-state decompostition of level human gait. Steady-state locomotion can be represented as a periodic sequence of states (or phases), where the transitions between the states are triggered by events within the gait cycle. The choice of the number of states and the type of events used are somewhat arbitrary, and will depend on what information is available from the sensors and which joint the P/O is to actuate. In this example for the knee joints, stance has been divided into three states, with early and middle stance initiated by ground contact events at the heel and toe of the foot, for example determined using pressure sensitive insoles. Late stance is triggered when the user’s center of mass is estimated to be over the ankle, again using the insoles or estimates of the user’s whole-body posture through joint position sensing or inertial measurements. Swing flexion begins as the toe of the foot leaves the ground, and swing extension begins as the knee’s velocity is sensed to be less than zero. The cycle begins again as the heel comes into contact with the ground.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 232 references

Cited by

See all 1,047

Metadata

Authors
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R.
Affiliations
  • ETH Zurich (CH)
  • École Polytechnique Fédérale de Lausanne (CH)
  • University of Zurich (CH)
Corresponding author
Tucker, Michael R
Venue
Journal of NeuroEngineering and Rehabilitation
Published
2015
Volume
12
Issue
1
Pages
1
ISSN
1743-0003 (ISSN-L)
OpenAlex
W2142114107
Cited by
1,047
References
232
Citations by year
2026: 42 · 2025: 69 · 2024: 72 · 2023: 119 · 2022: 102 · 2021: 161 · 2020: 116 · 2019: 108 · 2018: 92 · 2017: 85 · 2016: 61 · 2015: 20
FWCI
6.63
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
  • Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
  • Research Repository (Delft University of Technology) (submittedVersion, cc-by)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • ETH Zürich Research Collection (cc-by)
  • Zurich Open Repository and Archive (University of Zurich)
Funders
  • National Science Foundation
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Locomotion and Control
Keywords
orthoses, wearable robotic devices, gait assistance, control strategy, activities of daily living, sensorimotor control, hierarchical control architecture, safety mechanisms, regulatory approval
MeSH terms
Activities of Daily Living, Electromyography, Gait, Humans, Locomotion, Orthotic Devices, Prosthesis Design, Prostheses and Implants, Lower Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control strategies for active lower extremity prosthetics and orthotics: a review. https://app.cochat.ai/papers/10.1186/1743-0003-12-1
The paper
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015). Control strategies for active lower extremity prosthetics and orthotics: a review. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-12-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.