The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Cyber Security Resilience in Industrial Control Systems using Defence-in-Depth and Zero Trust
Open accessAbstract
An Industrial Control System (ICS) can be seen as a comprehensive class of automation systems employed to provide control and monitoring functionalities in manufacturing and industrial sectors. There has been a trend to include critical infrastructure across ICS sectors for safe and efficient operations. However, integrating critical infrastructure with public networks has exposed ICSs to cyber-attacks. As traditional ICSs have not been designed to handle security threats, existing vulnerabilities should be identified, and proper methods must be developed to make systems cyber-resilient. In this paper, we discuss the challenges of cyber security resilience in ICS networks. We provide the functionalities of an ICS architecture and vulnerabilities in an ICS network. Significantly, we discuss defence-in-depth for ICS networks based on prevention, detection, and incident response, and the incorporation of zero trust principles. Finally, we outline potential future activities to address those challenges.
Overview
CoChat Summary
TL;DR
This paper is a short conceptual discussion of cyber security resilience for industrial control systems (ICS), arguing that integrating critical infrastructure with public networks increases exposure to cyber-attacks. It proposes defence-in-depth and zero trust as key principles for improving resilience, but does not present empirical evaluation.
Key findings
- The paper states that traditional ICSs were not designed to handle security threats, so “existing vulnerabilities should be identified” and systems made “cyber-resilient.”
- It frames ICS resilience around three defence-in-depth functions: prevention, detection, and incident response.
- It specifically recommends incorporating zero trust principles alongside defence-in-depth.
- It also notes “potential future activities” to address the challenges, but does not report quantitative results.
Methods
- Conceptual discussion paper presented at the 16th International Conference on Sensing Technology (ICST) in 2023.
- The paper discusses ICS architecture, vulnerabilities in ICS networks, defence-in-depth, and zero trust based on the authors’ synthesis rather than on a reported dataset.
- Main analysis is descriptive and argumentative; no sample, experiment, or formal empirical method is stated in the text.
Limitations
- The paper does not state any empirical limitations because it does not report an experiment, dataset, or case study.
- Evident limitation: the text is high-level and conceptual, so its claims are not validated with measured outcomes, comparisons, or implementation results.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
No claims could be anchored to a verbatim quote in the text.
Citations
Cites
A fast quantum mechanical algorithm for database search
Grover, L. K. (1996) · Proceedings of the twenty-eighth annual ACM symposium on Theory of computing - STOC '96 · doi:10.1145/237814.237866 · Cited by 8,830
Zhang, F., Kodituwakku, H. A. D. E., Hines, J. W., & Coble, J. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2891261 · Cited by 362
A Survey on Industrial Control System Testbeds and Datasets for Security Research
Conti, M., Donadel, D., & Turrin, F. (2021) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3094360 · Cited by 247
Cybersecurity in industrial control systems: Issues, technologies, and challenges
Asghar, M. R., Hu, Q., & Zeadally, S. (2019) · Computer Networks · doi:10.1016/j.comnet.2019.106946 · Cited by 172
Assessing and augmenting SCADA cyber security: A survey of techniques
Nazir, S., Patel, S., & Patel, D. (2017) · Computers & Security · doi:10.1016/j.cose.2017.06.010 · Cited by 167 · cited 1×
“In ICS, the most important being Availability and Integrity followed by Confidentiality [2].”
BackgroundSCADA vulnerabilities and attacks: A review of the state‐of‐the‐art and open issues
Alanazi, M., Mahmood, A., & Chowdhury, M. J. M. (2023) · Computers & Security · doi:10.1016/j.cose.2022.103028 · Cited by 158
Review on cyber vulnerabilities of communication protocols in industrial control systems
Xu, Y., Yang, Y., Li, T., Ju, J., & Wang, Q. (2017) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2017.8245509 · Cited by 113
Formal modelling and analysis of DNP3 secure authentication
Amoah, R., Camtepe, S. A., & Foo, E. (2015) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2015.05.015 · Cited by 53
Self-citationWang, X., Fidge, C., Nourbakhsh, G., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3142022 · Cited by 50
Self-citationAutomated detection-in-depth in industrial control systems
Jadidi, Z., Foo, E., Hussain, M., & Fidge, C. (2022) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-021-08001-6 · Cited by 31
Self-citation
Research works printed but not linked: 2
- Collantes, 2015, Protocols and network security in ics infrastructures
- Profiles for the lightweight cryptography standardization process
Cited by
Countermeasures Management in Cyber Defense Exercises
Pavelka, M., & Hudec, L. (2024) · New Trends in Signal Processing (NTSP) · doi:10.23919/ntsp61680.2024.10726308 · Cited by 1
“The different approaches need to be seen as complementary elements, while thinking in a broader context (e.g. the ZeroTrust concept or the defense-in-depth concept) [1].”
BackgroundAhmadian, M. M., Rad, B. M., & Ahmadian, M. H. (2025) · International Conference on Protection and Automation of Power Systems (IPAPS) · doi:10.1109/ipaps65933.2025.11092272
“Jadidi et al. (2023) [10], explore the resilience of industrial control systems (ICS) by applying the defense-in-depth strategy and zero trust architecture.”
Metadata
- Authors
- Jadidi, Z., Pal, S., Li, Q., & Foo, E.
- Affiliations
- Griffith University (AU)
- Deakin University (AU)
- Venue
- 2023 16th International Conference on Sensing Technology (ICST)
- Publisher
- IEEE
- Published
- 2023-12-17
- Pages
- 1-6
- OpenAlex
- W4392944422
- Semantic Scholar
- d573982743117eff34d812d40519c2414a3ca179
- Cited by
- 2
- References
- 19
- Citations by year
- 2025: 1 · 2024: 1
- FWCI
- 0.86
- Type
- conference paper
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- International Conference on Sensing Technology (publishedVersion)
- Griffith Research Online (submittedVersion, other-oa)
- Deakin Research Online (Deakin University)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Security and Intrusion Detection
- Keywords
- industrial control systems, defense-in-depth, zero-trust architecture, critical infrastructure, cyberattacks, incident response, attack detection, network partitioning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-09 (model deepseek-v4.1-flash, prompt extract-v3).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cyber Security Resilience in Industrial Control Systems using Defence-in-Depth and Zero Trust. https://app.cochat.ai/papers/10.1109/icst59744.2023.10460853
- The paper
- Jadidi, Z., Pal, S., Li, Q., & Foo, E. (2023). Cyber Security Resilience in Industrial Control Systems using Defence-in-Depth and Zero Trust. 2023 16th International Conference on Sensing Technology (ICST). https://doi.org/10.1109/icst59744.2023.10460853
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.