The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
RUPERT: An exoskeleton robot for assisting rehabilitation of arm functions
Abstract
The design of a wearable upper extremity therapy robot RUPERT IV™ (Robotic Upper Extremity Repetitive Trainer) device is presented. It is designed to assist in repetitive therapy tasks related to activities of daily living which has been advocated for being more effective for functional recovery. RUPERT™ has five actuated degrees of freedom driven by compliant and safe pneumatic muscle actuators (PMA) assisting shoulder elevation, humeral external rotation, elbow extension, forearm supination and wrist/hand extension. The device is designed to extend the arm and move in a 3D space with no gravity compensation, which is a natural setting for practicing day-to-day activities. Because the device is wearable and lightweight, the device is very portable; it can be worn standing or sitting for performing therapy tasks that better mimic activities of daily living. A closed-loop controller combining a PID-based feedback controller and a Iterative learning controller (ILC)-based feedforward controller is proposed for RUPERT for passive repetitive task training. This type of control aids in overcoming the highly nonlinear nature of the plant under control, and also helps in adapting easily to different subjects for performing different tasks. The system was tested on two able-bodied subjects to evaluate its performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The coordination of arm movements: an experimentally confirmed mathematical model
Flash, T., & Hogan, N. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-07-01688.1985 · Cited by 4,395
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Upper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies
Proietti, T., Crocher, V., Roby-Brami, A., & Jarrasse, N. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2552201 · Cited by 388
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Metadata
- Authors
- Balasubramanian, S., Wei, R., Perez, M., Shepard, B., Koeneman, E., Koeneman, J., & He, J.
- Venue
- 2008 Virtual Rehabilitation
- Publisher
- IEEE
- Published
- 2008-08
- Pages
- 163-167
- OpenAlex
- W2125609926
- Cited by
- 194
- References
- 1
- FWCI
- 10.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: RUPERT: An exoskeleton robot for assisting rehabilitation of arm functions. https://app.cochat.ai/papers/10.1109/icvr.2008.4625154
- The paper
- Balasubramanian, S., Wei, R., Perez, M., Shepard, B., Koeneman, E., Koeneman, J., & He, J. (2008). RUPERT: An exoskeleton robot for assisting rehabilitation of arm functions. 2008 Virtual Rehabilitation. https://doi.org/10.1109/icvr.2008.4625154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.