Cascade multilevel inverters for utility applications
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Cascade multilevel inverters have been developed by the authors for utility applications. A cascade M-level inverter consists of (M-1)/2 H-bridges in which each bridge has its own separate DC source. The new inverter: (1) can generate almost sinusoidal waveform voltage while only switching one time per fundamental cycle, (2) can eliminate transformers of multipulse inverters used in conventional utility interfaces and static VAr compensators, and (3) makes possible direct parallel or series connection to medium- and high-voltage power systems without any transformers. In other words, the cascade inverter is much more efficient and suitable for utility applications than traditional multipulse and pulse width modulation (PWM) inverters. The authors have experimentally demonstrated the superiority of the new inverter for reactive power (VAr) and harmonic compensation. This paper summarizes features, feasibility, and control schemes of the cascade inverter for utility applications including utility interface of renewable energy, voltage regulation, VAr compensation, and harmonic filtering in power systems. Analytical, simulated, and experimental results demonstrate the superiority of the new inverters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J. W., & VanCoevering, J. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.536875 · Cited by 858
Self-citationA multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J., & VanCoevering, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530626 · Cited by 847
Self-citationComparison of multilevel inverters for static VAr compensation
Hochgraf, C., Lasseter, R., Divan, D., & Lipo, T. A. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.377528 · Cited by 354
Mori, S., Matsuno, K., Hasegawa, T., Ohnishi, S., Takeda, M., Seto, M., Murakami, S., & Ishiguro, F. (1993) · IEEE Transactions on Power Systems · doi:10.1109/59.221218 · Cited by 319
A power line conditioner using cascade multilevel inverters for distribution systems
Peng, F. Z., McKeever, J. W., & Adams, D. J. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629028 · Cited by 283
Self-citation
Cited by
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Self-citationA Review on Reduced Switch Count Multilevel Inverter Topologies
Omer, P., Kumar, J., & Surjan, B. S. (2020) · IEEE Access · doi:10.1109/access.2020.2969551 · Cited by 226
Metadata
- Authors
- Peng, F. Z., McKeever, J. W., & Adams, D. J.
- Venue
- Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)
- Publisher
- IEEE
- Published
- 2002-11-22
- Volume
- 2
- Pages
- 437-442
- OpenAlex
- W1921446515
- Cited by
- 165
- References
- 5
- FWCI
- 6.77
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.