LV distribution network voltage control mechanism: Experimental tests and validation
Abstract
Experimental test results of a voltage control mechanism for LV distribution networks are presented in this work. The main goal of the voltage control system is to mitigate over- and under voltages. The control mechanism uses the readily available flexibility of residential smart appliances. The main advantage of the control system is that it does not require a communication network between the different households within the LV network. The control system merely requires communication between the smart appliances within one household, and uses locally available measurements, such as the household supply voltage, e.g. provided by a smart meter. The control system is rolled out in the LINEAR residential demand response pilot for approximately 100 families, from December 2013.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electric vehicles and other similar large residential loads can be used flexibly.
“Furthermore, EVs and other similar, large residential loads presents can be used flexibly [8], [9].”
From Congestion mitigation in unbalanced residential networks with OPF-based demand management (2022) · cites this paper as [8]
Cited by
Sorted by citations
Congestion mitigation in unbalanced residential networks with OPF-based demand management
Vanin, M., Van Acker, T., Ergun, H., D’hulst, R., Vanthournout, K., & Van Hertem, D. (2022) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2022.100936 · Cited by 7 · see citing works
Self-citation
- Authors
- D'hulst, R., Vanthournout, K., & Hoornaert, F.
- Affiliations
- Flemish Institute for Technological Research (BE)
- KU Leuven (BE)
- Venue
- IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2014-10
- Pages
- 3504-3509
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W1504779239
- Cited by
- 8
- References
- 0
- Citations by year
- 2022: 1 · 2020: 1 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 1
- FWCI
- 1.62
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- Lirias (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- low-voltage distribution networks, voltage regulation, overvoltage suppression, demand response, smart meters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review