Analysis of stator inter-turn short-circuit fault signatures for inverter-fed permanent magnet synchronous motors
The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
Abstract
It is quite important to detect stator short-circuit fault, which is the most common fault type, at incipient stage. It is possible to carry out fault detection using Motor Current Signature Analysis (MCSA) method. In this study, stator current and voltage space vectors of PMSMs were analyzed with MCSA under various load torque, speed and fault percentages conditions. The Negative & positive harmonics were obtained by applying Fast Fourier Transform (FFT) to space vectors of stator current and voltage. It is suggested that by using the obtained fault signatures, stator inter-turn fault estimation can be achieved accurately. The results of comprehensive analysis carried out under various load torque and speed conditions show that characteristics fault signatures are both present in the current and the voltage space vectors spectra.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In [49] authors verified experimentally that both the current and the voltage negative sequence harmonics should be considered for accurate ITSC faults detection.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [49]
Citations
Cites
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Understanding digital signal processing
Lyons, R. G. (1996) · Cited by 1,019
The detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471
Ebrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Bearing Fault Detection Via Stator Current Noise Cancellation and Statistical Control
Zhou, W., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005018 · Cited by 165
Stone, G., & Kapler, J. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715501 · Cited by 99
Wu, Q. H., & Nandi, S. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2045329 · Cited by 92
Wu, L., Huang, X., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900542 · Cited by 59
Çıra, F., Arkan, M., & Gümüş, B. (2016) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2016.11.2.416 · Cited by 24
Self-citationGöktaş, T., Arkan, M., & Özgüven, Ö. F. (2013) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645706 · Cited by 19
Self-citation
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [49] authors verified experimentally that both the current and the voltage negative sequence harmonics should be considered for accurate ITSC faults detection.”
BackgroundMotor Fault Diagnostics Based on Current Signatures: A Review
Niu, G., Dong, X., & Chen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285999 · Cited by 269
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Stator Winding Fault Thermal Signature Monitoring and Analysis by In Situ FBG Sensors
Mohammed, A., Melecio, J. I., & Djurović, S. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2883260 · Cited by 83
Fault Detection of Stator Inter-Turn Short-Circuit in PMSM on Stator Current and Vibration Signal
Liang, H., Chen, Y., Liang, S., & Wang, C. (2018) · Applied Sciences · doi:10.3390/app8091677 · Cited by 71
Metadata
- Authors
- Cira, F., Arkan, M., Gumus, B., & Goktas, T.
- Venue
- IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2016-10
- Pages
- 1453-1457
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W2569562551
- Cited by
- 31
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 8 · 2022: 5 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 2
- FWCI
- 3.17
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, inverter-fed drives, motor current signature analysis, early fault detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of stator inter-turn short-circuit fault signatures for inverter-fed permanent magnet synchronous motors. https://app.cochat.ai/papers/10.1109/iecon.2016.7793717
- The paper
- Cira, F., Arkan, M., Gumus, B., & Goktas, T. (2016). Analysis of stator inter-turn short-circuit fault signatures for inverter-fed permanent magnet synchronous motors. IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society. https://doi.org/10.1109/iecon.2016.7793717
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.