Cited by 14Analytical Chemistry and SensorsAdvancements in Semiconductor Devices and Circuit DesignAnalog and Mixed-Signal Circuit Design

BioFET Technology: Aggressively Scaled pMOS FinFET as Biosensor

Martens, K., Santermans, S., Gupta, M., Hellings, G., Wuytens, R., Du Bois, B., Dupuy, E., Altamirano-Sanchez, E. +7 more·2019·2019 IEEE International Electron Devices Meeting (IEDM)

Abstract

We report for the first time on a BioFET sensor using FinFETs with 10nm wide fins built in a 300 mm pilot line. Our minimally modified finfet process uses a `Replacement Gate' strategy whereby the Si gate is pulled at the end of the process to form the cavity that holds the electrolyte. We used a pMOS FinFET as our electrolytic gate typically has a high work function of 5.0 eV. Changing the pH or binding biomolecules to the gate dielectric surface changes the threshold voltage (VT). Measuring the VT shift provides high sensitivity due to our high-quality gate dielectric. The median voltage referred 1/f noise of only ~500 μV2μm2/Hz (at 1Hz, at threshold), is significantly lower than other reported bioFETs. We obtain a pH sensitivity near the Nernstian limit of 57 mV/pH for HfO2. Drift of the sensor has been found to be adequate at -1 mV/hour. Finally, we have verified our device to act as a biomolecular transducer. We find the VT shift due to surface bound biomolecules for DNA grafting and PNA-DNA hybridization to be as expected from simulation. Based on our quantification of transduction and simulations we project which single molecule signal-to-noise ratios could ultimately be obtained in the future.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iedm19573.2019.8993589

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cited by

Sorted by citations

Authors
Martens, K., Santermans, S., Gupta, M., Hellings, G., Wuytens, R., Du Bois, B., Dupuy, E., Altamirano-Sanchez, E., Jans, K., Vos, R., Stakenborg, T., Lagae, L., Heyns, M., Severi, S., & Roy, W. V.
Affiliations
  • IMEC (BE)
  • KU Leuven (BE)
  • imec,Leuven,Belgium
Venue
2019 IEEE International Electron Devices Meeting (IEDM)
Publisher
IEEE
Published
2019-12
Pages
18.6.1-18.6.4
ISSN
0163-1918 (ISSN-L)
OpenAlex
W3005906113
Cited by
14
References
0
Citations by year
2026: 3 · 2025: 1 · 2024: 1 · 2021: 7 · 2020: 2
FWCI
6.95
Type
conference paper
Language
en
Open access
closed
Locations
Technical digest - International Electron Devices Meeting/Technical digest (publishedVersion)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
BioFET, FinFET, threshold voltage shift, pH sensing, HfO2 gate dielectric, 1/f noise, DNA hybridization, PNA-DNA hybridization, single-molecule detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review