The Neuropixels probe: A CMOS based integrated microsystems platform for neuroscience and brain-computer interfaces
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We review recent progress in neural probes for brain recording, with a focus on the Neuropixels platform. Historically the number of neurons' recorded simultaneously, follows a Moore's law like behavior, with numbers doubling every 6.7 years. Using traditional techniques of probe fabrication, continuing to scale up electrode densities is very challenging. We describe a custom CMOS process technology that enables electrode counts well beyond 1000 electrodes; with the aim to characterize large neural populations with single neuron spatial precision and millisecond timing resolution. This required integrating analog and digital circuitry with the electrode array, making it a standalone integrated electrophysiology recording system. Input referred noise and power per channel is 7.5μV and <; 50μW respectively to ensure tissue heating <; 1°C. This approach enables doubling the number of measured neurons every 12 months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190 · cited 1×
“As an example, Fig 4, shows data from a probe inserted into the brain of an awake, head-fixed mouse[7].”
BackgroundSelf-citationLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 3×
“Two of the most critical relate to the geometry: (a)supporting thousands of dense recording sites to isolate many neurons across large regions of the brain[2]; and (b) a small cross-sectional area to minimize tissue damage and foreign body rejection.”
BackgroundMethodInfluentialAccurate Estimation of Neural Population Dynamics without Spike Sorting
Trautmann, E. M., Stavisky, S. D., Lahiri, S., Ames, K. C., Kaufman, M. T., O’Shea, D. J., Vyas, S., Sun, X., Ryu, S. I., Ganguli, S., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.05.003 · Cited by 255
Self-citation
Cited by
Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
“S, IMEC) include an electrode shank (width: 70 µ m, length: 10 mm, thickness: 100 µ m) of 960 total sites laid out in a checkerboard pattern with contacts at ~18-µ m site-to-site distances (16 µ m (column), 20 µ m (row) 1,59 ).”
BackgroundSelf-citationHigh-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Self-citationHesse, J. K., & Tsao, D. Y. (2020) · eLife · doi:10.7554/elife.58360 · Cited by 78
“Recordings were performed using tungsten electrodes (FHC) with 1 MW impedance and, after correct targeting was confirmed, with 32-channel S-probes (Plexon) with 75 mm and 100 mm inter-electrode distance, and, in three sessions, with passive Neuropixels-like probe prototypes (IMEC) (Dutta et al., 2019; Jun et al., 2017…”
MethodChallenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
Metadata
- Authors
- Dutta, B., Andrei, A., Harris, T. D., Lopez, C. M., O’Callahan, J., Putzeys, J., Raducanu, B. C., Severi, S., Stavisky, S. D., Trautmann, E. M., Welkenhuysen, M., & Shenoy, K. V.
- Venue
- 2019 IEEE International Electron Devices Meeting (IEDM)
- Publisher
- IEEE
- Published
- 2019-12
- Pages
- 10.1.1-10.1.4
- ISSN
- 0163-1918 (ISSN-L)
- OpenAlex
- W3005632009
- Cited by
- 35
- References
- 3
- FWCI
- 12.15
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Neuropixels probe: A CMOS based integrated microsystems platform for neuroscience and brain-computer interfaces. https://app.cochat.ai/papers/10.1109/iedm19573.2019.8993611
- The paper
- Dutta, B., Andrei, A., Harris, T. D., Lopez, C. M., O’Callahan, J., Putzeys, J., Raducanu, B. C., Severi, S., Stavisky, S. D., Trautmann, E. M., Welkenhuysen, M., & Shenoy, K. V. (2019). The Neuropixels probe: A CMOS based integrated microsystems platform for neuroscience and brain-computer interfaces. 2019 IEEE International Electron Devices Meeting (IEDM). https://doi.org/10.1109/iedm19573.2019.8993611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.