Cited by 2,190Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignNeural dynamics and brain function

Fully integrated silicon probes for high-density recording of neural activity

Open access
Jun, James J., Steinmetz, Nicholas A., Siegle, Joshua H., Denman, Daniel J., Bauza, Marius, Barbarits, Brian, Lee, Albert K., Anastassiou, Costas A. +27 more·2017·Nature

Abstract

Sensory, motor and cognitive operations involve the coordinated action of large neuronal populations across multiple brain regions in both superficial and deep structures. Existing extracellular probes record neural activity with excellent spatial and temporal (sub-millisecond) resolution, but from only a few dozen neurons per shank. Optical Ca 2+ imaging offers more coverage but lacks the temporal resolution needed to distinguish individual spikes reliably and does not measure local field potentials. Until now, no technology compatible with use in unrestrained animals has combined high spatiotemporal resolution with large volume coverage. Here we design, fabricate and test a new silicon probe known as Neuropixels to meet this need. Each probe has 384 recording channels that can programmably address 960 complementary metal-oxide-semiconductor (CMOS) processing-compatible low-impedance TiN sites that tile a single 10-mm long, 70 × 20-μm cross-section shank. The 6 × 9-mm probe base is fabricated with the shank on a single chip. Voltage signals are filtered, amplified, multiplexed and digitized on the base, allowing the direct transmission of noise-free digital data from the probe. The combination of dense recording sites and high channel count yielded well-isolated spiking activity from hundreds of neurons per probe implanted in mice and rats. Using two probes, more than 700 well-isolated single neurons were recorded simultaneously from five brain structures in an awake mouse. The fully integrated functionality and small size of Neuropixels probes allowed large populations of neurons from several brain structures to be recorded in freely moving animals. This combination of high-performance electrode technology and scalable chip fabrication methods opens a path towards recording of brain-wide neural activity during behaviour.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/nature24636

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Neural activity was recorded using Neuropixels 1.0 silicon recording probes acutely inserted into the medial entorhinal cortex.

    “During behavior, neural activity was recorded using Neuropixels 1.0 silicon recording probes (Jun et al., 2017), which were acutely inserted into the medial entorhinal cortex”
  • Normative models of remapping do not address how a biological system might implement the strategy.

    “However, these normative models 29 (i.e., theories for why remapping occurs) do not address how a biological system might implement this strategy.”
  • Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes, with recent improvements bringing this number closer to one thousand, even on a single probe.

    “Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
  • The Neuropixels probe has a user-programmable switch that allows addressing 384 of the 960 sites simultaneously.

    “In addition, it has a user-programmable switch that allows us to address 384 of the 960 sites simultaneously.”

    From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jun et al., 2017

  • The Neuropixels probe is 10 mm long and contains 960 sites.

    “The probe is 10 mm long and contains 960 sites.”

    From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jun et al., 2017

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 33 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., Barbic, M., Blanche, T. J., Bonin, V., Couto, J., Dutta, B., Gratiy, S. L., Gutnisky, D. A., Häusser, M., Karsh, B., Ledochowitsch, P., Lopez, C. M., Mitelut, C., Musa, S., Okun, M., Pachitariu, M., Putzeys, J., Rich, P. D., Rossant, C., Sun, W.-L., Svoboda, K., Carandini, M., Harris, K. D., Koch, C., O’Keefe, J., & Harris, T. D.
Affiliations
  • Howard Hughes Medical Institute (US)
  • UCL Queen Square Institute of Neurology (GB)
  • Allen Institute for Brain Science (US)
  • IMEC (BE)
  • Neuroelectronics Research Flanders (BE)
  • University College London (GB)
  • University of Leicester (GB)
Corresponding author
Harris, Timothy D.
Venue
Nature
Published
2017-11-09
Volume
551
Issue
7679
Pages
232-236
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2767493192
Cited by
2,190
References
33
Citations by year
2026: 229 · 2025: 334 · 2024: 269 · 2023: 297 · 2022: 232 · 2021: 289 · 2020: 221 · 2019: 199 · 2018: 116 · 2017: 2 · 2016: 1
FWCI
71.96
Type
journal article
Language
en
Open access
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • UCL Discovery (University College London) (acceptedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
  • Leicester Research Archive (University of Leicester) (submittedVersion, other-oa)
Funders
  • Howard Hughes Medical Institute
  • Wellcome Trust (203020/Z/16/Z, 095668, 095669, 100154)
  • Academy of Medical Sciences (SBF002\1045)
  • Biotechnology and Biological Sciences Research Council (BB/P020607/1)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
Keywords
Neuropixels, silicon probes, high-density neural recording, extracellular recording, single-unit recording, freely moving animals
MeSH terms
Animals, Electrodes, Female, Male, Movement, Neurons, Semiconductors, Silicon, Wakefulness, Prefrontal Cortex, Entorhinal Cortex, Mice, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review