Obtaining skin contact force information from implanted nerve cuff recording electrodes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An investigation was conducted to determine how the electrical activity in a cutaneous nerve relates to the force applied on glabrous skin. Nerve cuff electrodes implanted on the tibial nerve of cats were used to record the electroneurogram (ENG) when the footpad was probed by a servo-controlled motor. The ENG signal was nonlinearly dependent on the applied force. It saturated for high forces, adapted when constant forces were applied, and was very sensitive to slippage. Linear system identification techniques provided estimates of force amplitude and frequency. Improved estimates were obtained using a real-time, analog, nonlinear filter that included proportional integral and exponential terms. Accurate estimations of input force could best be made if the force was not constant but varied in the 0.1-5.0-Hz range. Cuff electrodes implanted on nerves supplying glabrous skin of the hands or feet may provide feedback suitable, for example, for the closed-loop control of functional electrical simulation of paralyzed muscles in spinal cord injured patients.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Cited by
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
Information contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63
How to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
Self-citationPerspectives on the role of afferent signals in control of motor neuroprostheses
Johnson, K. O., Popović, D., Riso, R. R., Koris, M., Van Doren, C., & Kantor, C. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00003-6 · Cited by 16
Metadata
- Authors
- Hoffer, J. A., Haugland, M., & Li, T.
- Venue
- Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2003-01-13
- Pages
- 928-929
- OpenAlex
- W2104353092
- Cited by
- 13
- References
- 2
- FWCI
- 2.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.