Novel thin film titanium nitride micro-electrodes with excellent charge transfer capability for cell stimulation and sensing applications
The DOI matches its Crossref record.
Abstract
Microelectrodes with high specific charge transfer capability are an important prerequisite for high resolution stimulation, and recording of neuronal and muscular tissue. Novel thin film titanium nitride (TiN) microelectrodes were fabricated onto a microelectrode array by reactive sputtering in a nitrogen/argon atmosphere. The electrodes showed excellent charge transfer capacity of 40 mC/cm/sup 2/ and low ac-impedance along with high pulse stability. Scanning electron microscopy revealed a regular columnar morphology providing for a large internal surface area. With respect to their electrical and mechanical properties the TiN electrodes proved superior to electrodes produced by anodic oxidation of iridium. In this type of iridium oxide irregular cracks formed probably due to the high density ratio between metal and oxide. Furthermore, in spite of high charge capacity at very low frequencies (Q/sub cap/) the iridium oxide electrodes exhibited poor safe charge injection limit under pulsing conditions (Q/sub inj/).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
“that TiN electrodes could supply 22 mC/cm of charge [14].”
BackgroundWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Metadata
- Authors
- Janders, M., Egert, U., Stelzle, M., & Nisch, W.
- Venue
- Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2002-12-24
- Volume
- 1
- Pages
- 245-247
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2542395004
- Cited by
- 90
- References
- 0
- FWCI
- 17.38
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel thin film titanium nitride micro-electrodes with excellent charge transfer capability for cell stimulation and sensing applications. https://app.cochat.ai/papers/10.1109/iembs.1996.656936
- The paper
- Janders, M., Egert, U., Stelzle, M., & Nisch, W. (2002). Novel thin film titanium nitride micro-electrodes with excellent charge transfer capability for cell stimulation and sensing applications. Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.1996.656936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.