The DOI matches its Crossref record.
Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters
Abstract
Detection and tracking algorithms of the blood vessel network in the retinal images are proposed. Two main groups of algorithms are employed for this task, i.e., scanning and tracking. According to the known blood vessel feature, a second-order derivative Gaussian matched filter is designed and used to locate the center point and width of a vessel in its cross sectional profile. Together with this the extended Kalman filter is employed for the optimal linear estimation of the next possible location of blood vessel segment by appropriate formulation of its pattern changing process and observation model. To check the bifurcation in the vessel network, a simple branching detection strategy is implemented during tracking. The proposed algorithms all work well in the whole tracking process and can detect more complete vessel network in the ocular fundus photographs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
An Active Contour Model for Segmenting and Measuring Retinal Vessels
Al-Diri, B., Hunter, A., & Steel, D. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2017941 · Cited by 431
An approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
Metadata
- Authors
- Chutatape, O., Zheng, L., & Krishnan, S. M.
- Venue
- Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)
- Publisher
- IEEE
- Published
- 2002-11-28
- Volume
- 6
- Pages
- 3144-3149
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2152410740
- Cited by
- 228
- References
- 0
- FWCI
- 14.83
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters. https://app.cochat.ai/papers/10.1109/iembs.1998.746160
- The paper
- Chutatape, O., Zheng, L., & Krishnan, S. M. (2002). Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters. Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286). https://doi.org/10.1109/iembs.1998.746160
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.