Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present a new integrated device for monitoring heart rate at the wrist using an optical measure. Motion robustness is obtained by using accurate motion reference signals of 3D low noise accelerometers together with dual channel optical sensing. Nonlinear modelling allows to remove the motion contributions in the optical signals and the spatial diversity of the sensors is used to remove reciprocal contributions in the two channels. Finally a statistical estimation, based on physiological properties of the heart, gives a robust estimation of the heart rate. Qualitative and quantitative performance evaluation of the performances on real signals clearly show that the proposed system gives an accurate estimation of the heart rate, even under intense physical activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
“By assuming that the artifact is a linear addition to the PPG, the original signal can be reconstructed from the corrupted signal [112], [113].”
BackgroundGarbarino, M., Lai, M., Tognetti, S., Picard, R., & Bender, D. (2014) · Proceedings of the 4th International Conference on Wireless Mobile Communication and Healthcare - "Transforming healthcare through innovations in mobile and wireless technologies" · doi:10.4108/icst.mobihealth.2014.257418 · Cited by 215
“This technique is different from the common technique that exploits a single wavelength together with accelerometer information [1].”
MethodMotion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140
“The ε and d also depends on the wavelength of light, while the c and d can be time varying in case of motion [10]:”
BackgroundMultichannel reflective PPG earpiece sensor with passive motion cancellation
Wang, L., Lo, B. P., & Yang, G.-Z. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.910900 · Cited by 114
“These include the use of an accelerometer device to capture motion rhythms [11], [12] and the use of post-processing methods such as spatio-temporal PCA [ 13 ], Laguerre expansion [14], discrete wavelet analysis and filter banks [15], [16], Wigner‐Ville distribution [17] and nonlinear methods [18] for artifact removal.”
Method
Metadata
- Authors
- Renevey, P., Vetter, R., Krauss, J., Celka, P., & Depeursinge, Y.
- Venue
- 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-08-24
- Volume
- 3
- Pages
- 3030-3033
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2144923054
- Cited by
- 63
- References
- 1
- FWCI
- 13.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation. https://app.cochat.ai/papers/10.1109/iembs.2001.1017437
- The paper
- Renevey, P., Vetter, R., Krauss, J., Celka, P., & Depeursinge, Y. (2005). Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation. 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2001.1017437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.