Cited by 114Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlAdvanced Sensor and Energy Harvesting Materials

Multichannel reflective PPG earpiece sensor with passive motion cancellation

Wang, Lei, Lo, Benny PL, Yang, Guang-Zhong·2007·IEEE Transactions on Biomedical Circuits and Systems

Abstract

This paper addresses the design considerations of a novel earpiece photoplethymograph (PPG) sensor and its in-situ evaluation results. The device is encapsulated with multiple LEDs and photodiodes based on a reflective PPG design. A compact and low power circuitry was developed for signal control and conditioning. PPG signals with an averaged ac/dc ratio of 0.001-0.01 and 10% relative strength (compared to finger-based approach) were recorded from the superior and posterior auricular skins. The integrity of PPG signal and accuracy of heart rate detection were evaluated and the results showed that with adequate optical shielding and the proposed passive motion cancellation, the device was able to reliably detect heart rate both during rest and moderate exercise. The proposed sensor design is low power, easy to wear compared to conventional earlobe PPG devices.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2007.910900

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wang et al.'s ear-worn sensor method was effective in shielding from noise due to ambient light, as the DC level of the PPG signal was less than 2 nA when the LEDs were switched off.

    “This method was found to be effective in shielding from noise due to ambient light, as the DC level of the PPG signal was considerably low (measured to be less than 2 nA) when the LEDs were switched off.”

Cites

Flagged first, then by citations

2 of the 27 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Wang, L., Lo, B. P., & Yang, G.-Z.
Affiliations
Imperial College London (GB)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2007-12
Volume
1
Issue
4
Pages
235-241
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2109125512
Cited by
114
References
27
Citations by year
2026: 2 · 2025: 4 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 6 · 2019: 11 · 2018: 6 · 2017: 5 · 2016: 5 · 2015: 9 · 2014: 9 · 2013: 4 · 2012: 4
FWCI
4.30
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Funders
Engineering and Physical Sciences Research Council (EP/E044298/1, EP/C547586/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
photoplethysmography, heartbeat detection, optical shielding, exercise monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review