Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record.

Line length: an efficient feature for seizure onset detection

Esteller, R., Echauz, J., Tcheng, T., Litt, B., Pless, B.·2005·2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

A signal feature with low computational burden is presented as an efficient tool for seizure onset detection. The feature was evaluated over a total of. 1,215 hours of intracranial EEG signal from 10 patients. Results confirmed this feature as being useful for seizure onset detection yielding an average delay of 4.1 seconds, 0.051 false positives per hour, and one false negative on a subclinical seizure out of 111 seizures analyzed of which 23 were subclinical.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2001.1020545

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
Esteller, R., Echauz, J., Tcheng, T., Litt, B., & Pless, B.
Venue
2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2005-08-24
Pages
1707-1710
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2143776609
Cited by
250
References
0
FWCI
17.84
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Line length: an efficient feature for seizure onset detection. https://app.cochat.ai/papers/10.1109/iembs.2001.1020545
The paper
Esteller, R., Echauz, J., Tcheng, T., Litt, B., & Pless, B. (2005). Line length: an efficient feature for seizure onset detection. 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2001.1020545

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.