In-home wireless monitoring of physiological data for heart failure patients
The DOI matches its Crossref record.
Abstract
The current project proposes an integrated system (hardware and software) for real-time, wireless, remote acquisition of cardiac and other physiologic information from HF patients while in the home environment. Transducers for measurement of electrocardiogram (ECG), heart rate variability (HRV), acoustical data are embedded into patient clothing for unobtrusive monitoring for early, sensitive detection of changes in physiologic status. Sampling rate for this system is 1 kHz per channel. Signal conditioning is performed in hardware by the patient wearable system, after which information is wirelessly transmitted to a central server located elsewhere in the home for signal processing, data storage, and data trending. The dynamic frequency ranges for the ECG and heart sounds (HS) are 0.05-160 Hz and 35-1350 Hz, respectively. The range-of-operation for the current patient-wearable physiologic data capture design is 100/spl plusmn/10 feet with direct line-of-sight to the home server station. Weight measurements are obtained directly by the in-home medical server using a digital scale. Physiologic information (ECG, HRV, HS, and weight) are dynamically analyzed using a combination o the LabVIEW (National Instruments, Inc.; Austin, TX) and MATLAB (MathWorks, Inc.; Inc; Natick, MA) software strategies. Software-based algorithms detect out-of-normal or alarm conditions for HR and weight as defined by the health care provider, information critical for HF patients. Health care professionals can remotely access vital data for improved management of heart failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pervasive Healthcare and Wireless Health Monitoring
Varshney, U. (2007) · Mobile Networks and Applications · doi:10.1007/s11036-007-0017-1 · Cited by 685
Structured telephone support or telemonitoring programmes for patients with chronic heart failure
Inglis, S. C., Clark, R. A., McAlister, F. A., Ball, J., Lewinter, C., Cullington, D., Stewart, S., & Cleland, J. G. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007228.pub2 · Cited by 614
Structured telephone support or non-invasive telemonitoring for patients with heart failure
Inglis, S. C., Clark, R. A., Dierckx, R., Prieto-Merino, D., & Cleland, J. G. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007228.pub3 · Cited by 453
The adoption of mobile healthcare by hospital's professionals: An integrative perspective
Wu, I.-L., Li, J.-Y., & Fu, C.-Y. (2011) · Decision Support Systems · doi:10.1016/j.dss.2011.03.003 · Cited by 411
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Metadata
- Authors
- Mendoza, G. G., & Tran, B. Q.
- Venue
- Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2002
- Pages
- 1849-1850 vol.3
- OpenAlex
- W2163732972
- Cited by
- 52
- References
- 0
- FWCI
- 2.24
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-home wireless monitoring of physiological data for heart failure patients. https://app.cochat.ai/papers/10.1109/iembs.2002.1053058
- The paper
- Mendoza, G. G., & Tran, B. Q. (2002). In-home wireless monitoring of physiological data for heart failure patients. Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2002.1053058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.