CoChat

Adaptive reduction of motion artifact in the electrocardiogram

Tong, D.A., Bartels, K.A., Honeyager, K.S. · 2002 · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The electrocardiogram (ECG) is the body-surface manifestation of the electrical potentials produced by the heart. The ECG is acquired by placing electrodes on the patient's skin. Motion artifact is the noise that results from motion of the electrode in relation to the patient's skin. Motion artifact can produce large amplitude signals in the ECG that may be misinterpreted by clinicians and automated systems resulting in misdiagnosis, prolonged procedure duration, and delayed or inappropriate treatment decisions. Motion artifact reduction is an unsolved problem because its frequency spectrum overlaps that of the ECG. This paper presents initial results of a novel approach to reducing ECG motion artifact. The hypothesis is that motion artifact can be reduced using electrode motion as the reference signal to an adaptive filter. Electrode motion was measured with two custom-developed sensors that utilized anisotropic magnetoresistive sensors and accelerometers. Motion artifact was induced by manually pushing on the electrode, pushing on the skin around the electrode, and pulling on the lead wire. Using an adaptive filter and the motion signal, the induced motion artifact was reduced in all data sets.

Overview

Integrity signals

Registry

Crossref · 10.1109/iembs.2002.1106451

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 4 references

Research works printed but not linked: 1

  1. 1992, ANSI/AAMI EC1 1992

Cited by

See all 139

Metadata

Authors
Tong, D. A., Bartels, K. A., & Honeyager, K. S.
Affiliations
Southwest Research Institute (US)
Venue
Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
Publisher
IEEE
Published
2002
Pages
1403-1404 vol.2
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2166774198
Cited by
122
References
4
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 10 · 2021: 3 · 2020: 5 · 2019: 6 · 2018: 11 · 2017: 4 · 2016: 7 · 2015: 4 · 2014: 9 · 2013: 4 · 2012: 6
FWCI
5.48
Type
conference paper
Language
en
Open access
closed
Locations
Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
electrocardiogram, motion artifacts, artifact reduction, adaptive filtering, anisotropic magnetoresistive sensors, accelerometer, ECG noise, signal denoising

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive reduction of motion artifact in the electrocardiogram. https://app.cochat.ai/papers/10.1109/iembs.2002.1106451
The paper
Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002). Adaptive reduction of motion artifact in the electrocardiogram. Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2002.1106451

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.