Adaptive reduction of motion artifact in the electrocardiogram
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The electrocardiogram (ECG) is the body-surface manifestation of the electrical potentials produced by the heart. The ECG is acquired by placing electrodes on the patient's skin. Motion artifact is the noise that results from motion of the electrode in relation to the patient's skin. Motion artifact can produce large amplitude signals in the ECG that may be misinterpreted by clinicians and automated systems resulting in misdiagnosis, prolonged procedure duration, and delayed or inappropriate treatment decisions. Motion artifact reduction is an unsolved problem because its frequency spectrum overlaps that of the ECG. This paper presents initial results of a novel approach to reducing ECG motion artifact. The hypothesis is that motion artifact can be reduced using electrode motion as the reference signal to an adaptive filter. Electrode motion was measured with two custom-developed sensors that utilized anisotropic magnetoresistive sensors and accelerometers. Motion artifact was induced by manually pushing on the electrode, pushing on the skin around the electrode, and pulling on the lead wire. Using an adaptive filter and the motion signal, the induced motion artifact was reduced in all data sets.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By using additional sensors, such as triaxial accelerometers and gyroscopes, to synchronously monitor the movement, many methods have been proposed to detect and suppress the motion artifacts superimposed on MCG (ECG) signals, such as the adaptive filters (46) and the stationary wavelet transform (47, 48).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [46]
Citations
Cites
Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection
Thakor, N. V., & Zhu, Y.-S. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83591 · Cited by 885
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309 · cited 7×
“A percent improvement statistic ( 3 ) was calculated for all data sets using the noise-free data set as the "ideal" reference.”
BackgroundMethodInfluentialPhysician interpretation of electrocardiographic artifact that mimics ventricular tachycardia
Knight, B. P., Pelosi, F., Michaud, G. F., Strickberger, S. A., & Morady, F. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00627-1 · Cited by 82
Tremor-Induced ECG Artifact Mimicking Ventricular Tachycardia
Srikureja, W., Darbar, D., & Reeder, G. S. (2000) · Circulation · doi:10.1161/01.cir.102.11.1337 · Cited by 45
Research works printed but not linked: 1
- 1992, ANSI/AAMI EC1 1992
Cited by
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
“high sensitivity level combined with an ease of application; however, other sources such as anisotropic magnetoresistive (AMR) sensors [51], optical bend sensors, impedance sensors [52] and”
BackgroundFunctional near-infrared neuroimaging
Izzetoglu, M., Izzetoglu, K., Bunce, S., Ayaz, H., Devaraj, A., Onaral, B., & Pourrezaei, K. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847377 · Cited by 259
“Adaptive filtering has been widely used for noise reduction in other biomedical applications involving ECG, EEG and fNIR [ 12-15 ].”
MethodMotion Artifact Cancellation in NIR Spectroscopy Using Wiener Filtering
Izzetoglu, M., Devaraj, A., Bunce, S., & Onaral, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845243 · Cited by 173
Discrete-wavelet-transform-based noise removal and feature extraction for ECG signals
Lin, H.-Y., Liang, S.-H., Ho, Y., Lin, Y.-H., & Ma, H. (2014) · IRBM · doi:10.1016/j.irbm.2014.10.004 · Cited by 164
Advances in Soft and Dry Electrodes for Wearable Health Monitoring Devices
Kim, H., Kim, E., Choi, C., & Yeo, W. (2022) · Micromachines · doi:10.3390/mi13040629 · Cited by 139
“Motion artifact is a noise in the signal that is due to the movement of the electrode concerning the human skin caused by the motion of the subject [86], which affects the signal quality of the electrode.”
BackgroundWang, G., Zhang, C., Liu, Y., Yang, H., Fu, D., Wang, H., & Zhang, P. (2019) · Information Sciences · doi:10.1016/j.ins.2018.06.062 · Cited by 124
QRS Detection Algorithm for Telehealth Electrocardiogram Recordings
Khamis, H., Weiss, R., Xie, Y., Chang, C.-W., Lovell, N. H., & Redmond, S. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2549060 · Cited by 114
“over, techniques for artifact suppression and filtering of ECG signals are numerous in the literature [6]–[8].”
BackgroundA movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“…sensors, such as triaxial accelerometers and gyroscopes, to synchronously monitor the movement, many methods have been proposed to detect and suppress the motion artifacts superimposed on MCG (ECG) signals, such as the adaptive filters ( 46 ) and the stationary wavelet transform ( 47 , 48 ).”
Activity-aware ECG-based patient authentication for remote health monitoring
Sriram, J. C., Shin, M., Choudhury, T., & Kotz, D. (2009) · Proceedings of the 2009 international conference on Multimodal interfaces · doi:10.1145/1647314.1647378 · Cited by 85
“Tong et al. [33] and Raya and Sison [28] each proposed a noise-cancelling technique to compensate for motion artifacts in ECG data, by using additional sensors: an accelerometer and an anisotropic magnetore-298 sistive (AMR) sensor.”
MethodAppathurai, A., Carol, J. J., Raja, C., Kumar, S. N., Daniel, A. V., Malar, A. J. G., Fred, A. L., & Krishnamoorthy, S. (2019) · Measurement · doi:10.1016/j.measurement.2019.02.040 · Cited by 94
Electrocardiogram signal quality measures for unsupervised telehealth environments
Redmond, S. J., Xie, Y., Chang, D., Basilakis, J., & Lovell, N. H. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1517 · Cited by 83
Correlation Between Electrode-Tissue Impedance and Motion Artifact in Biopotential Recordings
Buxi, D., Kim, S., Helleputte, N. V., Altini, M., Wijsman, J., Yazıcıoğlu, R. F., Penders, J., & Hoof, C. A. V. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2221163 · Cited by 87
Bajaj, N., Carrión, J. R., Bellotti, F., Berta, R., & Gloria, A. D. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101624 · Cited by 85
Adaptive Motion Artifacts Reduction Using 3-axis Accelerometer in E-textile ECG Measurement System
Yoon, S. W., Min, S. D., Yun, Y. H., Lee, S., & Lee, M. (2007) · Journal of Medical Systems · doi:10.1007/s10916-007-9112-x · Cited by 70
“It leads wrong diagnosis and improper followup [4], and gives a challenge to be overcome for best healthcare provision.”
BackgroundWood, L. B., & Asada, H. H. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352374 · Cited by 51
“Widrow’s ANC has been utilized with accelerometer motion reference by the authors’ group [5], [6] and others [7] for motion artifact reduction in PPG sensors, as well as ECG sensors [8],[9].”
MethodA Wavelet Packets Approach to Electrocardiograph Baseline Drift Cancellation
Tinati, M. A., & Tazehkand, B. M. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/97157 · Cited by 60
“Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2006, Article ID 97157, Pages 1–9 DOI 10.1155/IJBI/2006/97157”
BackgroundInfluentialAdaptive Motion Artifact Reduction in Wearable ECG Measurements Using Impedance Pneumography Signal
An, X., Liu, Y., Zhao, Y., Lu, S., Stylios, G. K., & Liu, Q. (2022) · Sensors · doi:10.3390/s22155493 · Cited by 59
Removal of Motion Artifacts in Capacitive Electrocardiogram Acquisition: A Review
Sirtoli, V. G., Liamini, M., Lins, L. T., Lessard-Tremblay, M., Cowan, G. E. R., Zednik, R. J., & Gagnon, G. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3270661 · Cited by 58
“Other useful sources of reference signals are strain gauges [77], [78], electrode-tissue impedance (ETI) or electrode-skin impedance [68], [79], optical sensing [80], [81], anisotrophic magnetoresistive (AMR) sensors [82], and Ballistocardiogram [83].”
BackgroundKhalili, M., GholamHosseini, H., Lowe, A., & Kuo, M. M. Y. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03165-1 · Cited by 57
Reliable motion artifact detection for ECG monitoring systems with dry electrodes
Ottenbacher, J., Kirst, M., Jatobá, L., Huflejt, M., Grossmann, U., & Stork, W. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649502 · Cited by 56
“A common approach to improve artifact detection is to use information from additional signals that correlate to the motion artifact [5] [6].”
BackgroundA wavelet based technique for suppression of EMG noise and motion artifact in ambulatory ECG
Mithun, P., Pandey, P. C., Sebastian, T., Mishra, P., & Pandey, V. K. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091791 · Cited by 55
“[4] used adaptive filtering for reducing motion artifact with the output of an accelerometer, placed on the ECG electrode on the right arm, as the reference input.”
BackgroundMethodInfluentialPCA and ICA applied to noise reduction in multi-lead ECG
Romero, I. (2011) · Computing in cardiology · Cited by 55
Liu, Y., & PECHT, M. G. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260006 · Cited by 54
“Tong et al. [13], [ 14 ] monitored the electrode acceleration by attaching a 3-D accelerometer and a 2-axis anisotrophic magnetoresistive sensor respectively on the exposed surface of an electrode.”
Ghaleb, F. A. A., Kamat, M. B., Salleh, M., Rohani, M. F., & Razak, S. B. A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207176 · Cited by 50
“Moreover, they also reported that using the impulse train as reference distorts the P wave and T wave part in the ECG. Tong et al., [15] proposed an adaptive filter that utilized the electrode motion as the reference of the motion artefact.”
BackgroundMethodAdaptive filtering in ECG denoising: A comparative study
Romero, I., Geng, D., & Berset, T. (2012) · Computing in cardiology · Cited by 49
Impedance spectroscopy of changes in skin-electrode impedance induced by motion
Cömert, A., & Hyttinen, J. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-149 · Cited by 46
“These methods include optical sensors that detect the displacement of the skin [1-3], accelerometers that detect motion at the electrode [4-7], strain gauges that detect skin deformation [7,8], 2-d magneto resistive sensor components [4], electrode structures [9], contact pressure sensors [3], and skin-electrode imped…”
MethodMultichannel Techniques for Motion Artifacts Removal from Electrocardiographic Signals
Milanesi, M., Martini, N., Vanello, N., Positano, V., Santarelli, M. F., Paradiso, R., Rossi, D. D., & Landini, L. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260464 · Cited by 46
“Within this framework we investigate the use of a sensor for measuring the electrode movements under the hypothesis that the electrode motion contains information on motion artifact in ECG signal [ 6 ], [7].”
MethodElectrocardiographic Motion Artifact Versus Electrode Impedance
Wiese, S., Anheier, P., Connemara, R. D., Mollner, A. T., Neils, T. F., Kahn, J., & Webster, J. G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836503 · Cited by 46
“Others have suggested using physical sensors such as accelerometers tomeasure electrodemotion plus adaptive filters to cancel motion artifact [9], [10], but these methods have not been adopted.”
MethodAnsari, S., Ward, K. R., & Najarian, K. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2524646 · Cited by 43
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140783 · Cited by 42
“In fact, the information obtained from accelerometer and magneto-resistive sensors were recently used [37, 38].”
MethodChan, M., Ganti, V. G., & Inan, O. T. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3144990 · Cited by 42
Motion artifact removal based on periodical property for ECG monitoring with wearable systems
Zou, C., Qin, Y., Sun, C., Li, W., & Chen, W. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.026 · Cited by 41
“Afterwards, dozens of papers [10, 11, 12] utilize the framework to reduce motion artifacts in ECG signals using the acceleration signals as the reference signal.”
BackgroundWood, L. B., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260359 · Cited by 39
“Reference [ 8 ] used accelerometers placed at ECG electrodes to measure local disturbances, obtaining up to a 91% mean squared error reduction, where [9] used accelerometers placed at the lower back to measure bulk motion for running/jogging stress test patients and showed a significant improvement in ECG waveform con…”
MethodZhang, Z., Silva, I., Wu, D., Zheng, J., Wu, H., & Wang, W. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1201-7 · Cited by 39
“Contrary to other studies [20, 29, 38], ECG signal quality could not be improved impressively by adaptive filtering with the ACC outputs as the reference signals.”
MethodResultMotion artifact reduction in ambulatory ECG monitoring: an integrated system approach
Romero, I., Berset, T., Buxi, D., Brown, L., Penders, J., Kim, S., Helleputte, N. V., Kim, H. J., Hoof, C. A. V., & Yazicioglu, F. (2011) · Wireless Health · doi:10.1145/2077546.2077558 · Cited by 38
Flexible organic photodetectors and their use in wearable systems
Guo, H., Saifi, S., Fukuda, K., Cheng, H., Lou, Z., & Xu, X. (2021) · Digital Signal Processing · doi:10.1016/j.dsp.2021.103145 · Cited by 37
A Novel R Peak Detection Method for Mobile Environments
Lee, M., Park, D., Dong, S.-Y., & Youn, I. (2018) · IEEE Access · doi:10.1109/access.2018.2867329 · Cited by 37
“The effect of these artifacts can weaken the R peak spectrum, causing confusion in the P, Q, R, S, and T waveforms [10], or resulting in a large amplitude of noise signals in ECG signals [7], [10].”
BackgroundZhao, Z. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2306.01249 · Cited by 37
“However, they can be more challenging to interpret due to the potential for noise and artifacts introduced by physical movement [16].”
BackgroundPCA-based noise reduction in ambulatory ECGs
Romero, I. (2010) · Computing in cardiology · Cited by 36
Critical review of electrocardiography measurement systems and technology
Kalra, A. M., Lowe, A., & Al‐Jumaily, A. M. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaf2b7 · Cited by 35
Using DWT for ECG motion artifact reduction with noise-correlating signals
Kirst, M., Glauner, B., & Ottenbacher, J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091190 · Cited by 32
Ding, J., Tang, Y. F., Chang, R., Li, Y., Zhang, L., & Yan, F. (2023) · Sensors · doi:10.3390/s23020956 · Cited by 31
“Ottenbacher et al. decreased the motion artifact by introducing the variation in the electrode/skin impedance as the reference signal [17–20].”
BackgroundActivity Recognition in Wearable ECG Monitoring Aided by Accelerometer Data
Liu, J., Chen, J., Jiang, H., Jia, W. W., Lin, Q., & Wang, Z. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8351076 · Cited by 31
Choi, M., Jeong, J., Kim, S. J., & Kim, S. (2016) · Sensors · doi:10.3390/s16050715 · Cited by 30
“However, the conventional BPF is not effective in reducing motion noise, because the noise has a frequency spectrum that overlaps with the ECG spectrum [14].”
BackgroundCömert, A., & Hyttinen, J. (2014) · Physiological Measurement · doi:10.1088/0967-3334/36/1/1 · Cited by 29
EMG cancellation from ECG signals using modified NLMS adaptive filters
Hashim, F. R., Soraghan, J. J., Petropoulakis, L., & Daud, N. G. N. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047605 · Cited by 28
“Motion artifact is interference resulting from muscle movement at the electrodes which are placed onto the patient's skin and could produce large amplitude signals in the ECG which can then be misinterpreted and misdiagnosed [4].”
BackgroundCo-Located Multimodal Sensing: A Next Generation Solution for Wearable Health
Goverdovsky, V., Looney, D., Kidmose, P., Papavassiliou, C., & Mandic, D. P. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2338612 · Cited by 28
“approaches used magneto-resistive sensors [7], accelerome-”
Functional near-infrared neuroimaging
İzzetoğlu, K., Bunce, S. C., İzzetoğlu, M., Onaral, B., & Pourrezaei, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404489 · Cited by 28
R-R Interval Outlier Processing for Heart Rate Variability Analysis using Wearable ECG Devices
Eguchi, K., Aoki, R., Shimauchi, S., YOSHIDA, K., & Yamada, T. (2018) · Advanced Biomedical Engineering · doi:10.14326/abe.7.28 · Cited by 25
“One is applying lters to the target ECGs [10, 11].”
MethodYoon, S. H., Huo, K., & Ramani, K. (2016) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2016.04.008 · Cited by 24
“Nevertheless, they still adopt a touch-screen based input method due to the limitation of vision and biosignal based sensing such as occlusions and motion artifacts [1, 2].”
BackgroundOttenbacher, J., Kirst, M., Jatobá, L., Grossmann, U., & Stork, W. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_102 · Cited by 24
Reduction of Motion Artifacts In Electrocardiogram Monitoring Using an Optical Sensor
Liu, Y., & PECHT, M. G. (2011) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-45.2.155 · Cited by 21
Xiong, F., Chen, D., & Huang, M. (2020) · Sensors · doi:10.3390/s20040970 · Cited by 21
“[12] proposed an active adaptive filter for the reduction of motion artifacts.”
BackgroundA wearable heart rate belt for ambulant ECG monitoring
Peng, M., Wang, T., Hu, G., & Zhang, H. (2012) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2012.6379440 · Cited by 21
“It was shown in previous works that body motion signals can be used to improve R-wave detection [10-11] in ambulant ECG signal.”
Sebastian, T., Pandey, P. C., Naidu, S. M. M., & Pandey, V. K. (2011) · Computing in cardiology · Cited by 20
ECG electrodes for a context-aware cardiac permanent monitoring system
Ottenbacher, J., Jatobá, L., Grossmann, U., Stork, W., & Müller-Glaser, K. D. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_156 · Cited by 19
Adaptive reduction of motion artifact in a portable ECG system
Lee, W.-C., Yang, Y.-S. O., Ke, T.-C., Wei, C.-S., & Lee, H.-C. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690058 · Cited by 18
“The electrode acceleration signal was measured simultaneously with the ECG signal and used to estimate motion artifact with adaptive filtering [ 3 ].”
MethodRaggi, M., Moore, L. J., & Mesin, L. (2025) · IEEE Access · doi:10.1109/access.2025.3528518 · Cited by 17
Pholpoke, B., Songthawornpong, T., & Wattanapanitch, W. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2937536 · Cited by 17
“Many forms of reference signals have been employed for MA suppression such as the skin stretch signal [17], [28], the electrode motion [18], [19], the optical bend signal [29], and the change in electrode impedance (ETI) [29]–[31].”
BackgroundSeo, M., Choi, M., Lee, J. S., & Kim, S. W. (2018) · Sensors · doi:10.3390/s18072086 · Cited by 16
Hostettler, R., Lumikari, T., Palva, L., Nieminen, T. V. M., & Särkkä, S. (2018) · International Conference on Information Fusion (FUSION) · doi:10.23919/icif.2018.8455698 · Cited by 16
“) together with adaptive filtering approaches such as recursive least squares or least mean squares filtering with the raw accelerometer signal as the reference signal [9], [15]–[17].”
MethodWavelet approach to artifact noise removal from Capacitive coupled Electrocardiograph
Lee, S. M., Kim, K. K., & Park, K. S. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649820 · Cited by 16
“Therefore, many applications are introduced for ubiquitous healthcare cause ECGs of objects can be measured non-invasively and its electrically safety property: using displacement current rather than conduction current for many conventional ECG measurement equipments [1,2,3].”
BackgroundUse of power-line interference for adaptive motion artifact removal in biopotential measurements
Xu, L., Rooijakkers, M. J., Rabotti, C., Peuscher, J., & Mischi, M. (2015) · Physiological Measurement · doi:10.1088/0967-3334/37/1/25 · Cited by 15
“An accelerometer is most commonly used to measure the movement of an electrode (Tong et al. 2002, Xu et al. 2013), while electrode-skin impedance is also monitored by injecting an external current, providing a reference for noise cancelation (Degen & Jackel 2008, Serteyn et al. 2015).”
Single Scale CWT Algorithm for ECG Beat Detection for a Portable Monitoring System
Smaoui, G., Young, A., & Abid, M. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0212-2 · Cited by 15
Ansari, S., Ward, K., & Najarian, K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2316287 · Cited by 15
Discrete-wavelet-transform-based noise reduction and R wave detection for ECG signals
Lin, H.-Y., Liang, S.-Y., Ho, Y., Lin, Y., & Ma, H. (2013) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2013.6720700 · Cited by 15
“Adaptive filters were also used for reducing motion artifact, but the correct filter parameters are required.”
MethodWood, L. B. (2008) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 15
A real-time adaptive filtering approach to motion artefacts removal from ECG signals
Martini, N., Milanesi, M., Vanello, N., Positano, V., Santarelli, M. F., & Landini, L. (2010) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2010.032694 · Cited by 14
“The algorithm takes advantage of a multichannel acquisition scheme and requires a sensor for measuring the electrode movement under the hypothesis that the electrode motion contains information on motion artefact in ECG signal (Raya and Sison, 2002; Tong et al., 2002).”
MethodARGONAUT: An Inclusive Design Process for Wearable Health Monitoring Systems
Schauss, G., Arquilla, K. S., & Anderson, A. P. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3517590 · Cited by 14
“5 Hz- 20 Hz band pass IIR filter was used to remove noise from the electronics, respiration, metronome frequency, and other high frequency noise [30, 34, 42, 55].”
MethodSensor Based Smart Real Time Monitoring of Patients Conditions Using Wireless Protocol
Jegan, R., & Nimi, W. S. (2018) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.2018070105 · Cited by 14
Adaptive filtering for baseline wander removal in ECG
Pandey, V. K. (2010) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2010.5687642 · Cited by 14
“Adaptive filtering is used for suppressing several types of artifacts from biomedical signals [1], [3], [ 10 ].”
MethodMotion artifact removal in stress sensors used in “driver in motion” simulators
Affanni, A., Chiorboli, G., & Minen, D. (2016) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533719 · Cited by 13
A Wearable Electrocardiography Armband Resilient Against Artifacts
Zhou, Y., Mohaddes, F., Lee, C., Rao, S., Mills, A. C., Curry, A. C., Lee, B., & Misra, V. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3197060 · Cited by 13
“Noise from motion artifacts occurs over 237 a large amplitude range and often causes baseline distortion, 238 amplitude enlargement, or even the complete loss of ECG 239 pattern, according to Massachusetts Institute of Technology- 240 Beth Israel Hospital (MIT-BIH) Arrhythmia Database and 241 other research [7], [25].”
BackgroundEguchi, K., Aoki, R., YOSHIDA, K., & Yamada, T. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037072 · Cited by 10
“One is applying filters to the target ECGs [5, 6].”
MethodAdaptive motion artifacts reduction algorithm for ECG signal in textile wearable sensor
Yoon, S. W., Shin, H., Min, S. D., & Lee, M. (2007) · IEICE Electronics Express · doi:10.1587/elex.4.312 · Cited by 10
“This can lead to a wrong diagnosis result and improper follow-up [4].”
BackgroundInvestigation of Fault-Tolerant Adaptive Filtering for Noisy ECG Signals
Zhang, N. (2007) · IEEE Symposium on Computational Intelligence in Image and Signal Processing (CIISP) · doi:10.1109/ciisp.2007.369313 · Cited by 10
“Different filter structures are presented to eliminate the diverse form of noise: baseline wander, 60 Hz power line interference, muscle noise, and motion artifact [14], [15].”
BackgroundDevelopments in Ambulatory Electrocardiography
Eveloy, V. C., Liu, Y., & PECHT, M. G. (2006) · Biomedical Instrumentation & Technology · doi:10.2345/i0899-8205-40-3-238.1 · Cited by 10
Accelerometer based motion noise analysis of ECG signal
Han, D., Hong, J.-H., Shin, J.-I., & Lee, T. S. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03904-1_56 · Cited by 9
“Other researches attached accelerometers to electrode or device for the reference signal of adaptive filtering techniques[ 6-8 ].”
An Effective Adaptive Filter to Reduce Motion Artifacts from ECG Signals Using Accelerometer
Huang, M., Chen, D., & Xiong, F. (2019) · International Conference on Biomedical Engineering and Technology (ICBET) · doi:10.1145/3326172.3326214 · Cited by 9
“[1] proposed an adaptive filter for electrode motion artifacts caused by relative motion between the subject’s skin and electrode.”
BackgroundSalehizadeh, S. M. A., Noh, Y., & Chon, K. H. (2016) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase.2016.8 · Cited by 8
The Effect of White Noise and False Peak Detection on HRV Analysis
Manis, G., Alexandridi, A., Nikolopoulos, S., & Davos, K. (2005) · International Workshop on Biosignal Processing and Classification (BPC) · doi:10.5220/0001195301610166 · Cited by 8
“A sample of noise reduction techniques may be found in [10-12].”
BackgroundA Simple Bio-Signals Quality Measure for In-Home Monitoring
Sweeney, K., McLoone, S., & Ward, T. E. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0113 · Cited by 8
“Raya and Sison [5] and Tong et al.[3] used single axis ac-”
MethodInfluentialZhang, H., Zhao, H., & Guo, Z. (2024) · Sensors · doi:10.3390/s24123789 · Cited by 8
Pre-processing ECG signals for smart home material application
Vidhya, R. B., & Jerritta, S. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.11.367 · Cited by 7
Artifact Cancellation from Electrocardiogram by Mixed Wavelet-ICA Filter
Foresta, F. L., Mammone, N., & Morabito, F. C. (2006) · Lecture notes in computer science · doi:10.1007/11731177_12 · Cited by 7
“In particular, the artifact removal is often necessary for the clinical study of the electrocardiographic (ECG) signal [1], [2], [ 3 ].”
Investigation of Adaptive Filtering for Noisy ECG Signals
Zhang, N., Askildsen, B., & Hemmelman, B. T. (2006) · IEEE Mountain Workshop on Adaptive and Learning Systems · doi:10.1109/smcals.2006.250688 · Cited by 7
“Different filter structures are presented to eliminate the diverse form of noise: baseline wander, 60 Hz power line interference, muscle noise, and motion artifact [14], [ 15 ].”
BackgroundAdaptive R-Peak Detector in Extreme Noise Using EMD Selective Analyzer
Abderahman, H. N., Dajani, H. R., & Groza, V. Z. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856531 · Cited by 6
“Various factors contribute to this problem, such as the sensitivity of electronic devices, electrode contact surface, and motion artifacts [6-8].”
BackgroundGumPack: A Personal Health Assistant with Reconfigurable Surface Components
Li, K., & Warren, S. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.1.145 · Cited by 6
Eguchi, K., Aoki, R., YOSHIDA, K., & Yamada, T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513452 · Cited by 6
“There are two approaches to calculate accurate tHRV even from ECGs with noise or artifacts: accurate R wave detection [7-11] and RRI outlier exclusion [12, 13].”
MethodAoki, R., Eguchi, K., Shimauchi, S., YOSHIDA, K., & Yamada, T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513449 · Cited by 6
“Three approaches have been separately developed to calculate accurate HRV even from the ECG with noise or artifacts: accurate R wave detection [8-12], RRI outlier exclusion [13-15] and missing RRI complement [16, 17].”
MethodMotion artifact variability in biomagnetic wearable devices
Arekhloo, N. G., Wang, H., Parvizi, H., Tanwear, A., Zuo, S., McKinlay, M., Nuñez, C. G., Nazarpour, K., & Heidari, H. (2024) · Frontiers in Medical Technology · doi:10.3389/fmedt.2024.1457535 · Cited by 5
A stochastic fusion technique for removing motion artefacts from the measurements of a wireless ECG
Dargie, W. (2016) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2016.7849529 · Cited by 5
“[12] carry out a similar study, but this time, real 2D accelerometers and skin conductance sensors were embedded into ECG electrodes and all measurements were taken simultaneously.”
BackgroundMultimodal physiological sensor for motion artefact rejection
Goverdovsky, V., Looney, D., Kidmose, P., & Mandic, D. P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944193 · Cited by 5
“[6] have used electrode-skin impedance measurements as a means of motion artefact detection and estimation; others have experimented with magneto-resistive sensors [7], accelerometers [8], pressure sensors [9] and combinations of these [10] as well as electrode-skin halfcell potential monitoring [11].”
MethodAdaptive reduction of motion artefact in wireless physiological monitoring microsystems
Yang, Y.-S. O., Lee, W.-C., Ke, T.-C., Wei, C.-P., & Lee, C. (2008) · International Conference on Sensing Technology · doi:10.1109/icsenst.2008.4757161 · Cited by 5
“monitored the electrode acceleration signal measured simultaneously with the ECG signal and used to estimate motion artefact with adaptive filtering [5].”
MethodGhaleb, F. A. A., Kamat, M. B., Salleh, M., Rohani, M. F., & Hadji, S. E. (2017) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-319-59427-9_13 · Cited by 5
Lilienthal, J., & Dargie, W. (2020) · International Conference on Information Fusion (FUSION) · doi:10.23919/fusion45008.2020.9190621 · Cited by 4
“Previously, many approaches have been presented to remove motion artifact from the electrocardiogram: Independent Component Analysis [4], [5], Adaptive Filter [6]–[8], Wavelet Transformation [9]–[11], Tensor Decomposition [12] and a combination of these [13]–[15].”
MethodReview of Motion Artifacts Removing Techniques for Wireless Electrocardiograms
Dargie, W., & Lilienthal, J. (2020) · International Conference on Information Fusion (FUSION) · doi:10.23919/fusion45008.2020.9190525 · Cited by 4
“In the literature, attempts have been made to establish a correlation between the physical movements affecting the electrodes and the useful signal by using accelerometers, tilt, or contact sensors [3], [4], [5].”
BackgroundNoise cancellation of electrocardiogram signal measured by wearable USN node
Gautam, A., Lee, Y., & Chung, W. (2008) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2008.4648057 · Cited by 4
Reduction of periodic motion artifacts from impedance plethysmography
Ansari, S., Belle, A., Hobson, R. S., Ward, K., & Najarian, K. (2011) · IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW) · doi:10.1109/bibmw.2011.6112427 · Cited by 4
“For example, [15] uses acceleration signals obtained from 2-axis and 3-axis accelerometers as input to the LMS algorithm, and it concludes that the latter provides a higher performance in MA reduction.”
MethodHong, S., Song, K., Yan, L., & Yoo, H. (2010) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2010.5775062 · Cited by 4
“One of these methods is using accelerometers [5] and another method is using driven-right-leg (DRL) circuit [6].”
Method
Metadata
- Authors
- Tong, D. A., Bartels, K. A., & Honeyager, K. S.
- Affiliations
- Southwest Research Institute (US)
- Venue
- Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2002
- Pages
- 1403-1404 vol.2
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2166774198
- Cited by
- 122
- References
- 4
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 10 · 2021: 3 · 2020: 5 · 2019: 6 · 2018: 11 · 2017: 4 · 2016: 7 · 2015: 4 · 2014: 9 · 2013: 4 · 2012: 6
- FWCI
- 5.48
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- electrocardiogram, motion artifacts, artifact reduction, adaptive filtering, anisotropic magnetoresistive sensors, accelerometer, ECG noise, signal denoising
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.