Noise, in the form of motion artifact, often leads to false information and acts as a limiting factor in the analysis of pulse oximetric signals. We propose an adaptive filter for filtering motion artifacts from pulse oximetry signals, with accelerometer signals as noise references. We study two adaptive filtering schemes: (1) single-axis and (2) dual-axes stress tests; and apply both the LMS and RLS algorithms to each scheme to compare their effectiveness. Results show that a single-axis adaptive filter employing the RLS algorithm (N=32 and /spl lambda/=0.9999) is adequate to minimize motion artifact.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2002.1106644

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 60

Metadata

Authors
Relente, A. R., & Sison, L. G.
Venue
Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
Publisher
IEEE
Published
2002
Pages
1769-1770 vol.2
OpenAlex
W2124669095
Cited by
60
References
0
FWCI
0.45
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers. https://app.cochat.ai/papers/10.1109/iembs.2002.1106644
The paper
Relente, A. R., & Sison, L. G. (2002). Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers. Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2002.1106644

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.