Development of novel algorithm and real-time monitoring ambulatory system using Bluetooth module for fall detection in the elderly
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Novel algorithm and real-time ambulatory monitoring system for fall detection in elderly people is described. Our system is comprised of accelerometer, tilt sensor and gyroscope. For real-time monitoring, we used Bluetooth. Accelerometer measures kinetic force, tilt sensor and gyroscope estimates body posture. Also, we suggested algorithm using signals which obtained from the system attached to the chest for fall detection. To evaluate our system and algorithm, we experimented on three people aged over 26 years. The experiment of four cases such as forward fall, backward fall, side fall and sit-stand was repeated ten times and the experiment in daily life activity was performed one time to each subject. These experiments showed that our system and algorithm could distinguish between falling and daily life activity. Moreover, the accuracy of fall detection is 96.7%. Our system is especially adapted for long-time and real-time ambulatory monitoring of elderly people in emergency situation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk Factors for Falls among Elderly Persons Living in the Community
Tinetti, M. E., Speechley, M., & Ginter, S. F. (1988) · New England Journal of Medicine · doi:10.1056/nejm198812293192604 · Cited by 6,509 · cited 1×
“year, and among them, 24% have seriously injured [1], [3].”
BackgroundOliver, D., Britton, M., Seed, P., Martin, F. C., & Hopper, A. H. (1997) · BMJ · doi:10.1136/bmj.315.7115.1049 · Cited by 733 · cited 2×
“associated problems of subjectivity and limited accuracy in recall [1], [5], [6].”
BackgroundIncreased gait unsteadiness in community-dwelling elderly fallers
Hausdorff, J. M., Edelberg, H. K., Mitchell, S. L., Goldberger, A. L., & Wei, J. Y. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90034-4 · Cited by 593 · cited 1×
“detection system of gait, the systems leaded to unusual activity in daily lives of elderly people and rapid management between elderly people and a physician in emergence situation could not be performed [8], [9].”
BackgroundNajafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800763 · Cited by 442 · cited 4×
“associated problems of subjectivity and limited accuracy in recall [1], [5], [6].”
BackgroundInfluentialPatient Falls in Stroke Rehabilitation: A Challenge to Rehabilitation Strategies
Nyberg, L., & Gustafson, Y. (1995) · Stroke · doi:10.1161/01.str.26.5.838 · Cited by 408 · cited 1×
“associated problems of subjectivity and limited accuracy in recall [1], [5], [6].”
BackgroundThe sit-to-stand movement in stroke patients and its correlation with falling
Cheng, P.-T., Liaw, M.-Y., Wong, M.-K., Tang, F.-T., Lee, M.-Y., & Lin, P.-S. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90168-x · Cited by 342
Cited by
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
Bourke, A. K., O’Brien, J. V., & Lyons, G. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.012 · Cited by 821
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
Comparison of low-complexity fall detection algorithms for body attached accelerometers
Kangas, M., Konttila, A., Lindgren, P., Winblad, I., & Jämsä, T. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.003 · Cited by 493
Evaluation of Accelerometer-Based Fall Detection Algorithms on Real-World Falls
Bagalà, F., Becker, C., Cappello, A., Chiari, L., Aminian, K., Hausdorff, J. M., Zijlstra, W., & Klenk, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037062 · Cited by 464
Metadata
- Authors
- Hwang, J. Y., Kang, J. M., Jang, Y. W., & Kim, H. C.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 3
- Pages
- 2204-2207
- OpenAlex
- W2541166653
- Cited by
- 201
- References
- 6
- FWCI
- 7.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.