The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly
Open accessAbstract
A new method of evaluating the characteristics of postural transition (PT) and their correlation with falling risk in elderly people is described. The time of sit-to-stand and stand-to-sit transitions and their duration were measured using a miniature gyroscope attached to the chest and a portable recorder placed on the waist. Based on a simple model and the discrete wavelet transform, three parameters related to the PT were measured, namely, the average and standard deviation of transition duration and the occurrence of abnormal successive transitions (number of attempts to have a successful transition). The comparison between two groups of elderly subjects (with high and low fall-risk) showed that the computed parameters were significantly correlated with the falling risk as determined by the record of falls during the previous year, balance and gait disorders (Tinetti score), visual disorders, and cognitive and depressive disorders (p < 0.01). In this study, the wavelet transform has provided a powerful technique for enhancing the pattern of PT, which was mainly concentrated into the frequency range of 0.04-0.68 Hz. The system is especially adapted for long-term ambulatory monitoring of elderly people.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
Self-citation
Metadata
- Authors
- Najafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002-08
- Volume
- 49
- Issue
- 8
- Pages
- 843-851
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2156915253
- Cited by
- 442
- References
- 1
- FWCI
- 21.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly. https://app.cochat.ai/papers/10.1109/tbme.2002.800763
- The paper
- Najafi, B., Aminian, K., Loew, F., Blanc, Y., & Robert, P. A. (2002). Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2002.800763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.