CoChat

ECG Denoising Based on the Empirical Mode Decomposition

Weng, Binwei, Blanco-Velasco, Manuel, Barner, Kenneth E. · 2006 · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The electrocardiogram (ECG) has been widely used for diagnosis purposes of heart diseases. Good quality ECG are utilized by the physicians for interpretation and identification of physiological and pathological phenomena. However, in real situations, ECG recordings are often corrupted by artifacts. One prominent artifact is the high frequency noise caused by electromyogram induced noise, power line interferences, or mechanical forces acting on the electrodes. Noise severely limits the utility of the recorded ECG and thus need to be removed for better clinical evaluation. Several methods have been developed for ECG denoising. In this paper, we proposed a new ECG denoising method based on the recently developed Empirical Mode Decomposition (EMD). The proposed EMD-based method is able to remove high frequency noise with minimum signal distortion. The method is validated through experiments on the MIT-BIH database. Both quantitative and qualitative results are given. The results show that the proposed method provides very good results for denoising.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2006.259340

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A Real-Time QRS Detection Algorithm

    Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×

    “For example, it is known that, given a QRS complex, there is a 200 ms refractory period before the next one comes [ 9 ], which corresponds to 72 samples if the sampling frequency is 360 samples/s.”
    Background

Show all 1 references

Cited by

See all 140

Metadata

Authors
Weng, B., Blanco-Velasco, M., & Barner, K. E.
Venue
2006 International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2006-08
Volume
2006
Pages
1-4
OpenAlex
W2156855760
Cited by
140
References
1
FWCI
22.22
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ECG Denoising Based on the Empirical Mode Decomposition. https://app.cochat.ai/papers/10.1109/iembs.2006.259340
The paper
Weng, B., Blanco-Velasco, M., & Barner, K. E. (2006). ECG Denoising Based on the Empirical Mode Decomposition. 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2006.259340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.